Specifications

Manual # 016-0159-894 Rev H 01/07
291
12 - Troubleshooting
Job Issues
Issue Possible Cause Solution
Boom numbers
Boom switches Turn boom and master switch on.
are gray
are turned off
AccuBoom Move the machine out of the applied zone.
enabled but
machine not
moving
CAN is See the CAN Troubleshooting section.
disconnected
Boom number
The boom is not Check the boom setup from the Setup menu.
does not turn
set up properly
green when
turned on
Nodes not Check Node calibration and ensure all calibration
completely is completed.
programmed
The boom is Check the connection and wiring to the boom.
disconnected
Parallel
Boom switches Boom switches for Parallel AccuBoom must be in
AccuBooms will
on console are in the 'Off' position.
not turn off
the 'On' position
CAN AccuBoom
Boom switches Boom switches for CAN AccuBoom must be in
will not turn on
are in the 'Off' the 'On' position.
position
Product function
Not a CAN Product function keys work only in a CAN
keys do not work
system system.
Product Switch product application to either auto or
application is manual mode.
turned off
Dates and time
No GPS Make sure that the GPS receiver is operating
are incorrect
properly and that there is a green 'thumbs-up'
icon displayed in the GPS section of the main
screen.
No GPS RMC or Check the GPS receiver to make sure the RMC or
ZDA ZDA string is selected.
Incorrect time Verify the time zone selected in the Menu/Setup/
zone selected Local/Time Zone section.
Product spread in
Bed creep Adjust hydraulic valve to stop the bed creep.
zero rate zones
Wrong valve Must use either a Fast Close or PWM Close valve.
type on vehicle
Incorrect valve Check valve or PWM setting.
setting