Specifications
211
Manual # 016-0159-894 Rev H 01/07
7 - Using AutoBoom
Calibrating
UltraGlide In
PowerGlide
Plus Mode
The UltraGlide Autoboom system may be used in either the UltraGlide
mode or the PowerGlide Plus mode. You may want to run UltraGlide in
PowerGlide Plus mode when you are doing pre-emergence applications
where the booms are closer to the ground. Gauge wheels can be added to
the booms to further protect the booms under these conditions.
Important: If you are running in PowerGlide Plus
mode, you must have Autoboom gauge wheels
installed on both booms.
1. Select PowerGlide Plus under the Mode area in the upper left
hand corner of the Autoboom Control screen. The following screen
will display.
2. Press the Calibrate button. If ultrasonic sensors are connected
to the system and detected by Autoboom, the Calibrate UltraGlide
screen displays.