RE_240-1CA20
Manual VIPA System 200V Chapter 3 Deployment
HB97E - CP - RE_240-1CA20 - Rev. 12/42 3-31
Byte Function Range of values Default
parameters
0 Baud rate 00h: Default (9600Baud)
01h: 150Baud
02h: 300Baud
03h: 600Baud
04h: 1200Baud
05h: 1800Baud
06h: 2400Baud
07h: 4800Baud
08h: 7200Baud
09h: 9600Baud
0Ah: 14400Baud
0Bh: 19200Baud
0Ch:38400Baud
0Dh:57600Baud
0Fh: 76800Baud
0Eh: 115200Baud
00h: 9600Baud
1 Protocol 03h: 3964
04h: 3964R
05h: 3964 + RK512
06h: 3964R + RK512
03h: 3964
2 Bit 1/0
Data bits
00b: 5 Data bits
01b: 6 Data bits
10b: 7 Data bits
11b: 8 Data bits
11b: 8 Data bits
Bit 3/2
Parity
00b: none
01b: odd
10b .even
11b: even
00b: none
Bit 5/4
Stop bits
01b: 1
10b: 1.5
11b: 2
01b: 1 Stop bit
Bit 7/6
Flow control
reserved -
3 reserved 0 0
4 ZNA (*20ms) 0 ... 255 0
5 ZVZ (*20ms) 0 ... 255 10
6 QVZ (*20ms) 0 ... 255 25
7 BWZ (*20ms) 0 ... 255 100
8 STX repetitions 0 ... 255 5
9 DBL 0 ... 255 6
10 Priority 0: low
1: high
0: low
11 reserved
12 reserved
13 reserved
14 reserved
15 reserved
Structure of
parameter bytes for
3964(R) / 3964(R)
with RK512