RE_240-1CA20
Chapter 3 Deployment Manual VIPA System 200V
3-30 HB97E - CP - RE_240-1CA20 - Rev. 12/42
Byte Function Range of values Default
parameters
0 Baud rate 00h: Default (9600Baud)
01h: 150Baud
02h: 300Baud
03h: 600Baud
04h: 1200Baud
05h: 1800Baud
06h: 2400Baud
07h: 4800Baud
08h: 7200Baud
09h: 9600Baud
0Ah: 14400Baud
0Bh: 19200Baud
0Ch: 38400Baud
0Dh: 57600Baud
0Fh: 76800Baud
0Eh: 115200Baud
00h: 9600Baud
1 Protocol 02h: STX/ETX 02h (STX/ETX)
2 Bit 1/0
Data bits
00b: 5 Data bits
01b: 6 Data bits
10b: 7 Data bits
11b: 8 Data bits
11b: 8 Data bits
Bit 3/2
Parity
00b: none
01b: odd
10b: even
11b: even
00b: none
Bit 5/4
Stop bits
01b: 1
10b: 1.5
11b: 2
01b: 1 Stop bit
Bit 7/6
Flow control
00b: none
01b: Hardware
10b: XON/XOFF
00b: none
3 reserved 0 0
4 ZNA (*20ms) 0 ... 255 0
5 TMO (*20ms) 1 ... 255 10
6 Number of start flags 0 ... 2 01
7 Start flag 1 0 ... 255 02
8 Start flag 2 0 ... 255 0
9 Number of end flags 0 ... 2 01
10 End flag 1 0 ... 255 03
11 End flag 2 0 ... 255 0
12 reserved
13 reserved
14 reserved
15 reserved
Structure of
parameter bytes
for STX/ETX