User manual

CHAPTER 4. NETWORK CONFIGURATION 18
With the current firmware only manual configuration is supported. Automatic configuration using DHCP is
not supported.
Connectivity Monitor settings are used when WAN redundancy functionality is wanted. Monitor keeps checking
the connection to given remote host to determine the network status. If the ping does not get an answer for given
time window, it informs the WAN switch logic to try the secondary interface.
If the WAN redundancy is implemented by using two separated Ethernet connections with different gate-
ways, the Backup Gateway parameter needs to be configured towards correct backup gateway. Backup Gateway
parameter is not needed if WAN redundancy is implemented with wireless connection.
See section 4.1.4 for more details about WAN redundancy.
4.1.3 Mobile WAN (3G)
This screen configures the Mobile WAN (3G) interface on Arctic 3G.
Figure 4.3: Mobile WAN configuration
To configure the mobile WAN (3G), enable the connection by selecting Enable”=”Yes” on the top of the
page and enter PIN code if set, APN name and authentication details if needed.
If Arctic 3G acts as a wireless router to Ethernet devices and DNS is needed, enter DNS configuration as well.
When ready, press the Submit button on the bottom of the page to save settings.
Arctic 3G needs to be restarted before 3G configuration gets active.
4.1.4 WAN Failover
WAN Failover screen configures the default gateway settings on the Arctic 3G.