Specifications

8 / 15
3.5. Configuring the environment
1. If you’re using PuTTY, start by clicking the Serial button and change the Speed from
"9600" to "19200".
2. The Serial line should match the serial port where the null modem cable is connected to
your computer; typically it is "COM1". You may wish to check which serial (COM) ports are
in use. In Windows XP, go to Control panel
Æ
System
Æ
Hardware
Æ
Device Manager
Æ
Ports (COM&LPT) and check which “COM” ports are available, if any. If you do not
have serial ports at all, consider using USB-to-serial adapter.
3. Now you can click Open to open the serial connection between your computer and Arctic.
4. If you encounter problems in connecting, check the rest of the serial settings by clicking the
Serial menu-item from the left tab of the Putty Window. The settings should be as follows:
Serial line to connect to: COM1
(or the respective available COM-port in your PC)
Speed (baud): 19200
Data bits: 8
Stop bits: 1
Parity: None
Flow control: None
In Windows HyperTerminal the respective configuration would be as in the following
picture: