Use and Care Manual
- 18 -
5. WM-4510HZD remote-mount with cold-air supply and cellar-air return
ducts (Fig. 4.8)
1) Cut two circular openings at the wine cellar ceiling or wall as illustrated.
2) Secure the cooling unit on the top of the wine cellar or other strong flat places
3) Remove the front cover of the cooling unit.
4) Attach the duct hoods to the front the cooling unit with screws.
5) Attach the insulated ducts to the hoods with adhesive tapes.
6) Secure the ducts with conduits to the wine cellar ceiling and exterior walls and
make sure they are not curled, twisted, bent and clogged.
7) Install a rear exhaust grille and an air filter at the rear of the cooling unit.
8) Plug the unit into a properly grounded and dedicated outlet of adequate
capacity.
9) Turn the evaporator fan control knob counter-clockwise to achieve the
required air flow CFM.
Fig. 4.8 Cold-air supply and cellar-air return ducts