Operating instructions
!
Installing and Operating Instructions 
Vinotemp      1/3 
Digital controller with off cycle defrost and 
Fan Control 
CONTENTS 
1.  GENERAL WARNING ____________________________________________________1 
2.  GENERAL DESCRIPTION ________________________________________________1 
3.  CONTROLLING LOADS __________________________________________________1 
4.  FRONT PANEL COMMANDS ______________________________________________1 
5.  MAX & MIN TEMPERATURE MEMORIZATION _______________________________1 
6.  MAIN FUNCTIONS ______________________________________________________2 
7.  PARAMETERS _________________________________________________________2 
9.  TTL SERIAL LINE – FOR MONITORING SYSTEMS____________________________2 
11.  INSTALLATION AND MOUNTING __________________________________________3 
12.  ELECTRICAL CONNECTIONS _____________________________________________3 
13.  HOW TO USE THE HOT KEY______________________________________________3 
14.  ALARM SIGNALS _______________________________________________________3 
15.  TECHNICAL DATA ______________________________________________________3 
16.  CONNECTIONS_________________________________________________________3 
17.  DEFAULT SETTING VALUES______________________________________________3 
1.  GENERAL WARNING 
1.1  PLEASE READ BEFORE USING THIS MANUAL 
•  This  manual is  part  of  the  product  and  should  be kept  near  the  instrument  for  easy  and 
quick reference. 
•  The instrument shall not be  used for purposes different from those described hereunder. It 
cannot be used as a safety device. 
•  Check the application limits before proceeding. 
1.2 
SAFETY PRECAUTIONS 
•  Check the supply voltage is correct before connecting the instrument. 
•  Do  not  expose  to  water  or  moisture: use the controller only  within the  operating  limits 
avoiding sudden temperature changes with high atmospheric humidity to prevent formation 
of condensation 
•  Warning: disconnect all electrical connections before any kind of maintenance. 
•  Fit the  probe  where  it  is not  accessible  by the  End  User.  The instrument  must  not be 
opened. 
•  In case of failure or faulty operation send the instrument back to the distributor
 with a
detailed description of the fault. 
•  Consider the maximum current which can be applied to each relay (see Technical Data). 
•  Ensure that the wires for probes, loads and the power supply are separated and far enough 
from each other, without crossing or intertwining. 
•  In case of applications in industrial environments, the use of mains filters (our mod. FT1) in 
parallel with inductive loads could be useful. 
2.  GENERAL DESCRIPTION 
Model 30  format  32  x  74  mm, is a  digital thermostat  with  off  cycle  defrost  designed  for 
refrigeration  applications at  normal temperature.  It  provides  two  relay  outputs, one for the 
compressor, the other one can be used as light, for alarm signalling or as auxiliary output.. It is 
also provided with 1 or 2 NTC probe inputs the first one for temperature control, the second one, 
optional, to connect to the HOT KEY terminals to signal the condenser temperature alarm or to 
display a temperature. The digital input can operate as third temperature probe. 
The HOT KEY output allows to connect the unit, by means of an external module, to a network 
line compatible. 
It allows to program the controller by means the HOT KEY programming keyboard.  
The instrument  is fully configurable through special parameters that can be easily programmed 
through the keyboard. 
3.  CONTROLLING LOADS 
3.1  COMPRESSOR 
The  regulation  is  performed 
according  to  the  temperature 
measured  by  the  thermostat  probe 
with a  positive  differential  from the 
set  point:  if  the  temperature 
increases and reaches  set point plus 
differential  the  compressor is  started 
and  then  turned  off  when  the 
temperature  reaches  the  set  point 
value again. 
Time
Temper.
Compr.
SET
ON
In case of fault in the thermostat probe the start and stop of  the compressor are timed through 
parameters “COn” and “COF”. 
3.2  DEFROST 
Defrost  is  performed  through  a simple  stop of  the compressor.  Parameter  “IdF”  controls  the 
interval between defrost cycles, while its length is controlled by parameter “MdF”. 
4.  FRONT PANEL COMMANDS 
: To display target set point; in programming mode it selects a parameter or confirm an 
operation. 
  (DEF) To start a manual defrost 
 (UP): To see the max. stored temperature; in programming mode it browses the parameter 
codes or increases the displayed value. 
 (DOWN) To see the  min  stored temperature; in  programming  mode  it  browses  the 
parameter codes or decreases the displayed value. 
O/I  To turn ON or OFF the controller (if enabled) 
KEY COMBINATIONS: 
 +  
To lock & unlock the keyboard. 
 +    To enter in programming mode. 
 +  ! To return to the room temperature display. 
4.1  CONTROL OF EVAPORATOR FANS 
The fan control mode is selected by means of the “FnC” parameter: 
FnC = C_n: fans will switch ON and OFF with the compressor and not run during defrost; 
FnC = o_n  fans will run even if the compressor is off, and not run during defrost; 
After defrost, there is a timed fan delay allowing for drip time, set by means of the “Fnd” 
parameter. 
FnC = C_Y  fans will switch ON and OFF with the compressor and run during defrost; 
FnC = o_Y  fans will run continuously also during defrost 
An  additional  parameter “FSt” provides  the  setting  of temperature,  detected  by  the evaporator 
probe, above which the fans are always OFF. This is used to make sure circulation of air only if 
his temperature is lower than set in “FSt”. 
4.1.1  Cyclical activation of the fans with compressor off. 
When  Fnc  =  c-n  or  c-Y  (fans  in  parallel  to  the  compressor),  by  means  of  the  Fon  and  FoF 
parameters the fans can carry out on and off cycles even if the compressor is switched off. When 
the compressor is stopped the fans go on working for the Fon time. With Fon =0 the fans remain 
always off, when the compressor is off. This increases humidity in the system. 
4.2  USE OF LEDS 
Each LED function is described in the following table. 
LED 
MODE 
FUNCTION 
ON 
Compressor enabled 
Flashing 
Anti-short cycle delay enabled 
ON 
Defrost enabled 
ON 
An alarm is occurring 
°C/°F 
ON 
Measurement unit 
°C/°F 
Flashing 
Programming phase 
5.  MAX & MIN TEMPERATURE MEMORIZATION 
5.1  HOW TO SEE THE MIN TEMPERATURE 
1.   Press and release the n  key. 
2.   The “Lo” message will be displayed followed by the minimum temperature recorded. 
3.   By pressing the n key again or by waiting 5s the normal display will be restored. 