Specifications
- 7 -
4. Engage union nut on manifold pipe with male fitting on next appliance and draw union hand tight.
Be sure broilers butt both front and rear.
5. If manifolds do not line up, units are not level.
6. If the broiler is installed on the end of the battery and the top of the front top does not line up with
the adjacent unit, adjust front tops by means of bolts on the underside before replacing the manifold
cover and installing the valve handles.
7. Continue to level up and connect manifold pipe until all appliances in the battery are connected.
Then tighten manifold unions gas tight.
GAS CONNECTIONS
All gas supply connections and any pipe joint compound used must be resistant to the action of propane
gases.
Connect gas supply to the broiler(s). Make sure the pipes are clean and free of obstructions, dirt, and
piping compound.
Codes require that a gas shutoff valve be installed in the gas line ahead of the broiler.
Natural gas broilers and propane gas broilers are equipped with fixed orifices and no adjustment is
necessary.
The gas manifold of this broiler, or battery of which it is a part, must be connected to a pressure
regulator (not supplied) with a preset outlet pressure of 6" W.C. (Water Column) for natural gas or 10"
W.C. for propane gas. The regulators must have:
• A.G.A. design certification.
• Enough regulation capacity for the total connected gas load.
• Pressure adjustment range to allow adjustment for the manifold pressure marked on the rating
plate.
Unless the manifold pressure on all connected broilers is the same, a separate regulator must be
supplied for each broiler having different manifold pressures.
Be sure all burner and pilot valves are in a closed position. Turn on gas supply and check for leaks.
WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS.
USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.
After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.
Ensure that burner heads are connected.
Adjust burners making sure they line up with burner nozzles and that all burner baffle plates are
hanging in the proper position.