Specifications

- 5 -
The installation location must allow adequate clearances for servicing and proper operation. A
minimum front clearance of 36" is required.
The broiler must be installed so that the flow of combustion and ventilation air will not be obstructed.
Adequate clearance for air openings into the combustion chamber must be provided. Make sure there
is an adequate supply of air in the room suitable for the amount of combustion gas feeding the broiler
burners.
INSTALLATION CODES AND STANDARDS
Install this equipment in accordance with:
1. State and local codes, or in the absence of local codes, with:
2. National Fuel Gas Code, ANSI-Z223.1 (latest edition), available from the American Gas Association,
Inc., 1515 Wilson Blvd., Arlington, VA 22209.
3. National Electrical Code ANSI/NFPA 70 (latest edition).
For broilers equipped with casters, the installation shall be made with a connector that complies with
the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 (latest edition), and a quick-
disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas
Fuel, ANSI Z21.41 (latest edition). Provide a gas line strain relief to limit movement of the broiler
without depending on the connector and any quick-disconnect device or its associated piping to limit
the broiler movement. Attach the strain relief to the rear of the broiler (Fig. 1). Should it be necessary
to disconnect the restraint, turn off the gas supply before disconnection. Reconnect the restraint before
turning the gas supply on and returning the char broiler to its installation position.
Fig. 1
CONNECT GAS
LINE STRAIN
RELIEF HERE
PL-51216