VIKING installation instructions and safety information VIKING BLUE ENABLED SOLAR EFFICIENT OPERATION class I, class II, class III, and class IV residential and commercial vehicular swing gate operator
The standard specifications and features of the X-9™ gate operator showcase the commitment made in its concept and design. Whether it’s the simple, clean installation, energy efficient operation, or advanced battery backup function, this operator stands alone in its class. Included with the standard package are high quality direct burial cable, the complete control center and the X-9™ operator.
X-9 Vehicular Gate Operator • Revision C3 • November 2009
PARTS PARTS DIAGRAM DIAGRAM Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Description Part No.
TABLE TABLE OF OF CONTENTS CONTENTS Parts Diagram/Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i Important Safety Information Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Important Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3 Maintenance/General Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Terminology . . . . . .
IMPORTANT IMPORTANT SAFETY SAFETY INFORMATION INFORMATION WARNING - Not following these instructions may cause severe injury or death to persons. IMPORTANT SAFETY INSTRUCTIONS WARNING – To reduce the risk of severe injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the gate operator monthly.
IMPORTANT IMPORTANT SAFETY SAFETY INFORMATION INFORMATION WARNING - Not following these instructions may cause severe injury or death to persons. IMPORTANT INSTALLATION INSTRUCTIONS Continued 6. Controls intended for user activation must be located at least six feet (6’) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls.
IMPORTANT IMPORTANT SAFETY SAFETY INFORMATION INFORMATION WARNING - Not following these instructions may cause severe injury or death to persons. MAINTENANCE Remove the Power Harness from the Control Board (refer to page 17) • Clean and lubricate the turning pins and gate hinges using the recommended lubricant. • Check that all mounting hardware of the gate operator is properly tighten. • Ensure that the gate moves freely. • Check for corroded parts and replace if necessary.
IMPORTANT IMPORTANT SAFETY SAFETY INFORMATION INFORMATION CAUTION: To Reduce the Risk of Fire or Injury to Persons a) Use only the following type and size of battery(ies): Yuasa NP7-12 b) Do not dispose of the battery(ies) in fire. The cells may explode. Check with local codes for possible disposal instructions. c) Do not open or mutalate the battery(ies). Released electrolyte is corrosive and may cause damage to the eyes or skin. It may be toxic fi swallowed.
Reopen Loop Obstruction Charger Loop Radio Rec. Sensor UL Sens Center Loop Center SAFETY Safety UL Radio IMPORTANT IMPORTANT SAFETY INFORMATION INFORMATION Sensor Obstruction ay Loop Sensor Rec. Power WARNING - Not following these instructions may cause severe injury or death to persons. Low Battery NOTE when Sensor the photo-beam MAX- This type of installation DOES NOT reverse the gate all the way back to its limits Motor Check Motor is obstructed.
min. Motor Sensor Check Motor MAX Mag. Lock Mag. LOCK Lock MAG. WARNING - Not following these instructions may cause severe injury or death to persons. Off 1 COM N.O. 3-Sided Edge Sensor 3-Sided Edge Sensor +28v Gnd Gnd +28v Radio Station Gnd UL Gnd Gnd Safety Loop Connector Connector Reopen Gnd Exit Gnd Strike Gnd Fire Open Commands Gnd N.C. Edge Sensor (contact sensor) Installation Center 60 30 Open Open Mag.
IMPORTANT IMPORTANT SAFETY SAFETY INFORMATION INFORMATION WARNING - Not following these instructions may cause severe injury or death to persons. Audible Alarm Reset Switch Installation Manual Reset for the Audible Alarm UL325 standard requires an audibleJP3alarm to go off after two consecutive events detected by the primary entrapment protection of the gate operator (obstruction sensor). The audible alarm will continue to sound for 5 minutes or until a stop command C35 C36 gets actuated. Obstruction 1.
IMPORTANT IMPORTANT INSTALLATION INSTALLATION INFORMATION INFORMATION CAUTION - FOR USE WITH GATES OF A MAXIMUM OF 14 FT IN LENGTH AND 600 LBS. IN WEIGHT. WARNING - TO REDUCE THE RISK OF SEVERE INJURY OR DEATH TO PERSONS: This is NOT a pedestrian gate operator Do NOT Install the gate operator to lift gates 14'-0" OPEN STOP CLOSE Control Buttons 14’ maximum gate length Locate Control Buttons: 1. Within sight of the gate, 600 lb. MAX. 600 pounds maximum gate weight 2.
PLAN PLAN OF OF INSTALLATION INSTALLATION -- OPEN OPEN INSIDE INSIDE The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas. C: 23-1/2" Outside Gate in Closed Position Note: When application dictates dimension (A) to be between 12”-18”, both the Primary and Secondary arms may be extended EQUALLY, up to 6” each.
PLAN PLAN OF OF INSTALLATION INSTALLATION –– OPEN OPEN OUTSIDE OUTSIDE The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas. Outside Gate in Open Position 90° C: 19-1/2" Gate in Closed Position A: 11-3/4" Max. G: 4.33" Ref. H: 2.55" Ref.
GATE GATE OPERATOR OPERATOR INSTALLATION INSTALLATION CAUTION - If mounting bar is not welded to a frame member that runs the full length of the gate, the gate operator may damage the gate. Do not weld the bar or backing plate to a few pickets. STEP 1 14.173" 5.90" Check the integrity of the gate structure and sufficiently sturdy such as pivot points are properly lubricated and surfaces are free of rust. 5.90" 1.181" 3.937" a) Remove the Motor/Gear Assembly from its package.
GATE GATE OPERATOR OPERATOR INSTALLATION INSTALLATION STEP 4 Remount the geared motor on the chassis accordingly. STEP 5 Attach the Articulated Arms with the Positive Stop Extension to the Pivot Bracket and the Motor/Gear Assembly. NOTE - Additional holes are provided in the Pivot Bracket to assist with proper installation STEP 6 With the cover off, perform the Manual Release procedure as shown at the bottom of page 7. The gate can now be moved manually. Ensure that the gate and gate operator move freely.
GATE GATE OPERATOR OPERATOR INSTALLATION INSTALLATION Limit Switch Setup STEP 8 Additional Cam Mounting Holes A. Loosen the screws on the limit switch cams and position the cams to the desired locations. There are additional holes provided in case of a wide or tight angle of opening or closing. B. Move the gate manually and ensure that the limit switch gets actuated at the desired open and closed position. The limit switch will click when engaged by the limit cam. C.
GATE GATE OPERATOR OPERATOR INSTALLATION INSTALLATION Opening/Closing Setup: To have the gate operator slow down prior to reaching its limits use the following steps: 1. Setup the limit switches manually at the desired open and close position. 2. Allow the gate operator to run a full open and close cycle (from limit to limit) without interruption. Note: During the first full open and close cycle: The gate operator doesn’t slow down prior to reaching its limits.
CONTROL CONTROL BOX BOX INSTALLATION INSTALLATION WARNING - If the control box is not mounted properly it may fall, causing damage and/or injury. The control box weight is approximately 40 lbs. Be sure that the substrate being mounted to and the fasteners being used are appropriate to support the weight of the control box. 1. Remove the control board mounting plate. The plate is held in the box by four screws. 17" 2. Position the control box in the desired place and mark the mounting holes.
ELECTRICAL ELECTRICAL INSTALLATION INSTALLATION Caution – Do not connect the power harness to the board until the installation is ready for verification. Power Harness The X-9 Gate Operator requires a single phase AC line to operate and charge the batteries. 1. Turn off the main switch or breaker for the power line being used. 2. Move the selector switch on the Incoming Voltage Selector to the proper position (115 for 110 to 120VAC, 230 for 200 to 240VAC). 3.
ELECTRICAL ELECTRICAL INSTALLATION INSTALLATION –– SINGLE SINGLE UNIT UNIT Single Unit Connections Connect the wires from the motor unit to the terminal block mounted next to the control board. Match wire colors to the terminal block. Obstruction Overlap Delay Open Center Loop Sensor Sensor 1.5 OPEN LEFT Connect the wire harness to the “OPEN RIGHT” connector if the gate opens towards the right side. Connect the wire harness to the “OPEN LEFT” connector if the gate opens towards the left side.
ELECTRICAL ELECTRICAL INSTALLATION INSTALLATION –– MASTER/SLAVE MASTER/SLAVE Master/Slave Connections A Master/SlaveControl Board is available, when required, to run two gate operators in synchronous mode.
VEHICULAR VEHICULAR LOOP LOOP DETECTOR DETECTOR INSTALLATION INSTALLATION ide s p t Ou tside n Loo Ou eope R oop rL nte Ce ide Ins n ope Re p Loo t Exi p Loo i Ins de Note: Not all loops may be necessary for every installation. Check local regulations and accepted bestpractice design requirements.
VEHICULAR VEHICULAR LOOP LOOP DETECTOR DETECTOR INSTALLATION INSTALLATION WARNING – Consult the installation instructions from the loop detector manufacturer. The following statements are provided as a guide but different requirements may be required by the vehicular loop detector manufacturer. Guidelines for Vehicular Loop Detector Installation 1. Prevent sharp corners in the geometry of the loop sensor. 2. Install the appropriate number of turns for your loop geometry based on the loop perimeter.
Hold Open Timer OPEN LEFT UL Sens Mag. Lock Mag. LOCK Lock MAG. +28v Inside Photo Beam TECHNICAL SUPPORT 1 800 908 0884 +28v Gnd UL Gnd Mag. Lock COM N.O. +28v Gnd +28v Radio Gnd +28v Gnd UL Gnd Reopen Gnd Center Gnd N.C. Outside 22 Photo Beam COM Gnd +28v Radio Gnd +28v Gnd UL Gnd Reopen Gnd Gnd Center Off 1 Exit Edge Sensor N.C. Radio Station N.O. As an alternative to the Outside Reopen Loop, Radio Station a photo beam unit can be used as shown.
Safety Loop UL Sensor Charger Radio Rec. UL Sens Center Loop Radio Rec. Reopen Loop ACCESSORY ACCESSORY CONNECTIONS CONNECTIONS Center Loop on Power Note: All controls are normally open. Radio Receiver Low Battery Motor Sensor Check Motor AX When connecting the Radio Receiver carefully verify the proper connections. The maximum voltage that the control board provides for external accessories is the maximum voltage of the battery, which is about 28 volts. Mag.
M-2 ™ VIKING VIKING ELECTROMAGNETIC ELECTROMAGNETIC LOCK LOCK Standard Features Mounting base with electrical box Mounting Plate/Juction Box (Weld to Post) 24VDC Plug-in transformer Magnetic Lock 12VDC or 24VDC operation Mounting Screw (4) 500mA at 12VDC operation Mounting Screw Weather Cover (4) 250mA at 24VDC operation 1300 pounds of holding force Floating Plate • • • • • • Guide Pin (2) Use long or short pin depending on number of spacers used Flexible Washer Mounting Plate Floating Plate Magneti
OPEN RIG 24VAC Magnetic Lock Off 1 +28v Gnd COM Sensor MAX Hold Open Timer 2 N.O. N.O. N.O. OPEN STOP CLOSE COM 24 TECHNICAL SUPPORT 1 800 908 0884 25 Gnd Exit Gnd Strike Gnd Gnd Fire Open Commands Open Stop Close GND Open Stop Guard Station Center Off 1 Open 30 Hold Open Timer 60 Place the control switch box within sight of the gate, away from moving parts of the gate and out of reach of children.
SPECIAL SPECIAL FEATURES FEATURES Intelligent Obstruction Sensor (Primary Entrapment Protection) 0 Center Loop Sensor Obstruction Safety Loop Se MAX Hold Open Timer Turning the Trim Pot clockwise increases the sensitivity. Hold Open Open Turning the Trim Pot counterTimer clockwise decreases the sensitivity. Open 60 1. Stop the gate’s movement and reverse it momentarily. Off 1 Stop Close Center Loop Sensor min.
SPECIAL SPECIAL FEATURES FEATURES Gate Overlap Setting Setting the Overlap Delay Pot to “0” will cause the master and the slave units to open and close at the same time A Master/Slave control board is required to operate two gates with a single controller. Obstruction Overlap Delay Cen Lo Sensor 1.
SPECIAL SPECIAL FEATURES FEATURES Auto-Open Feature 0 Mag. Lock Mag. LOCK Lock MAG. N.C. N.O. TECHNICAL SUPPORT 1 800 908 0884 +28v 28 Radio Gnd +28v Radio S Gnd UL Gnd Reopen Gnd Center Safety Loop Connector Connector COM Gnd Radio Rec. Reopen Loop UL Sens Mag. Lock Off 1 Gnd Exit Gnd Strike Gnd Fire Open Commands Gnd Open Stop Close Guard Station GND Open Stop Close GND Siren Mag. Lock Mag. LOCK Lock MAG. +28v Radio Gnd Radio Rec.
h C nd Ex it St r ds an m m o C nd G G nd n pe O Fi re 60 O pe n D n io at St rd ua G N X A G M e lo s ve la /S et r as M lo C se 36 C 3 C ak e 35 n Br m . in Radio Rec. JP Charger Power Mag. LOCK Lock MAG. Mag. Lock Check Motor N.C. COM N.O. +28v Gnd +28v Radio Radio Station If you are using the computer: • Hold the computer near the Gate Operator. • Run the application by clicking the icon on the desktop. • Select “Setting” in the top right of the screen.
Safety Loop Connector Connector Radio Station N.O. COM N.C. Mag. Lock Mag. Lock Connect the Solar Panel Controller as shown. Check Motor Motor Sensor Low Battery Power Charger – + – Remove existing batteries. Use new external batteries of 35 AHr or greater and connect them in series to provide a 24V system. 30 TECHNICAL SUPPORT 1 800 908 0884 24VAC + Fail Safe/Secure 24V BAT Remove the existing Power Harness and use the power harness provided. Radio Rec.
ector ctor Radio Station Mag. LOCK Lock MAG. N.O. COM N.C. Mag. Lock OPTIONAL OPTIONALSOLAR SOLAR PANEL PANEL INSTALLATION INSTALLATION Mag. Lock For Viking Vehicular Gate Operators Check Motor Motor Sensor WARNING – Solar Panel must be UL Listed, Class 2 Low Battery Power Charger il ecure Replace the existing batteries with a battery pack of 35AHr or greater.
VIKING VIKING PIPE PIPE STAND STAND Part No. VA-X9PS For Viking X-9 Vehicular Gate Operator Standard Features • Main pieces made of 1/4” thick material • All hardware included Gate When installing the Pipe Stand Assembly, refer to Plan of Installation in the X-9 installation manual. 14.56" 9.5" 6.36" with 2-1/2” IPS Pipe (2.875” OD) 3.00"O.D.
TROUBLESHOOTING TROUBLESHOOTING Gate does not run – Motor Sensor indicator comes ON Check all motor connections to be fully engaged. Refer to page 18 and 19. Ensure that the motor connections are: a) Properly connected; b) Tight enough and; c) Match color code. Refer to page 15. Check that all motor cable connections, junctions and extensions are properly connected and color-coded. Refer to page 15.
TROUBLESHOOTING TROUBLESHOOTING Gate does not open or close Check all motor connections to be fully engaged. Refer to page 15. Check that limit switches are connected to the common and the normally close position refer to page 15. Check that the stop command is not active. Refer to page 8 and 25. Check that the UL command (photo beam and/or edge sensor) is not active. Refer to page 6, 7 and 22. Check that the vehicular loop detectors are working properly. Refer to page 20, 21 and 22.
TROUBLESHOOTING TROUBLESHOOTING Gate opens after few second delay Set the overlap delay trim pot to 0. Refer to page 27. Note: Overlap trim pot is normally recommended to use in overlapping gates. Refer to page 27. Gate opens. Closes or stops on its own Check that your external devices are working properly Check that your wires from your accessories are: a) Not shorting together b) Not shorting a power line c) Not shorting to metal or earth ground.
Notes
Notes
Notes
our continuous commitment to excellence Viking Access Systems is continuously working hard to identify and design products that will appeal to the industry and it’s needs. As technology continues to advance, we have developed a completely efficient and intelligent line of gate operators to meet the changing demands. These machines offer; full UL325 and UL991 compliance, soft-start and soft-stop, intelligent obstruction sensors, continuous operation (100% duty cycle) and extreme power efficiency.
VIKING standard features and operator specifications UL325 and UL991 Listed by Underwriter Laboratories (UL) • Accessible manual release via key operated mechanism • Standard Auto Open feature • Easy solution for complex installations • Elegant design, appealing to any architectural project • HIgh impact resistant and UV protected plastic cover • Opening up to 130° • Operation speed of 10 to 13 seconds per 90° • 100% duty cycle under very wide temperature range • Very low power consumption • 800 cycles of