Service manual
PROGRAMMING
4-25
April 2001
Part No. 001-9800-203
NOTE: Refer to Section 4.6.5 for more information on programming the parameters in the following table.
Table 4-4 Conventional System Parameters
Parameter Available Responses Description
Alpha Tag A-Z, 0-9, etc. Changes the eight-character alpha tag for the selected system. The system
alpha tag is displayed only by high tier models which have the alpha tag
display mode enabled (Section 3.4.4).
Channel Table 1 only - Low tier
1-3 - High tier
With low tier models, only one channel table is available, so this number is
always “1”. With high tier models, up to three tables can be programmed
and this number selects the one used by the system (Section 4.7.2).
Scan List Yes, No Programs the default scan list status of the system. This programming can
be overridden by A/D key if it is enabled (Section 3.7.2).
Group Scan Enabled, Disabled Programs if group scanning occurs on the system. If “Disabled” is
programmed, it cannot be selected (Section 3.7.1).
Emergency System/
Group; Automatic
(high tier only)
Any programmed system/
group. Automatic = N/A
Emergency calls are available only with high tier models. This programs
the system/group used for emergency calls on the system. If no system/
group is programmed, the bank system/group is used. Automatically trans-
mitted calls are not available with LTR 98xx models (Section 3.5.6).
Power Level Low tier - High, Low
High tier - High, Low 1,
Low 2, Low 3, Low 4
Programs the output power selected by this system. The power output pro-
duced by these levels is set during alignment (Section 3.5.14).
Companding Yes, No Programs if optional companding is used on the system (Section 3.5.4).
The output line controlling companding must also be programmed for that
function (Section 4.9).
Talk-Around Allowed Yes, No Programs if talk-around can be programmed on any of the groups in the
system (Section 3.9.4).