Service manual

PROGRAMMING
4-23
September 1999
Part No. 001-9800-200
Parameter Available Responses Description
Transmit Inhibit ID 1-250 Programs the block of transmit inhibit ID codes up to all 250. If an ID code
within this block is decoded up to 5 seconds before the PTT switch is
pressed, the transmitter does not key (Section 3.8.6).
Block Decode 1-250 Programs a block of ID codes up to all 250 that are decoded regardless of
the group selected (Section 3.8.1).
Power Level Low tier - High, Low
High tier - High, Low 1,
Low 2, Low 3, Low 4
Programs the output power selected by the system. The power output pro-
duced by these levels is set during alignment (Section 3.5.14).
Busy Queue Yes, No Programs if Busy Queuing is enabled on the system (Section 3.8.7).
Group Scan Enabled, Disabled Programs if group scanning occurs on the system. If “Disabled” is
programmed, it cannot be selected (Section 3.7.1).
Scan List Yes, No Programs the default scan list status of the system. This programming is
overridden by A/D key if it is enabled (Section 3.7.2).
Companding Yes, No Programs if optional companding is used on the system (Section 3.5.4).
The output line controlling companding must also be programmed for that
function (Section 4.9).
Priority 1/2 Decode 1-250 Programs the priority decode (receive) ID codes (Section 3.8.3).
Priority 1/2 Call Light Yes, No Programs if the Call indicator lights when a call is received on that priority
ID code (Section 3.5.3).
Priority 1/2 Horn Yes, No Programs if the horn sounds when a call is received on that ID code
(Section 3.5.10).
Priority 1/2 Encrypt Yes, No Programs if encryption is used on calls received on that ID code (Section
3.5.7).
Channel Table 1 only - Low tier
1-3 - High tier
With low tier models, only one channel table is available, so this number is
always “1”. With high tier models, up to three tables can be programmed,
and this number selects the table used by the system (Section 4.7.2).
Emergency System/
Group; Automatic
(high tier only)
Any programmed system/
group. Automatic = N/A
Emergency calls are available only with high tier models. This programs
the system/group used for emergency calls on the system. If no system/
group is programmed, the bank system/group is used. Automatically trans-
mitted calls are not available with LTR 98xx models (Section 3.5.6).
NO./CHN
(Number/Channel)
Any channel number from
channel table
Programs the channels of the LTR repeaters accessed by the system. These
are the channels assigned in the above channel table, not FCC channel
numbers. Press F3 to display the channel table (Sections 4.7.1 and 4.7.2).
RIC Yes, No Programs if the repeater is equipped with an interconnect controller
(Section 4.7.3).
Table 4-3 LTR System Parameters (Continued)