Service manual

PROGRAMMING
4-20
April 2001
Part No. 001-9800-203
Parameter Available Responses Description
Priority 1 Sampling
Time
Disabled, 500 ms, 1 or 2
seconds
Selects how often the Priority 1 system/group (if programmed) is sampled
on conventional systems (Section 3.9.6).
Select Knob Default
(high tier only)
Systems or Groups Programs if the system or group select mode is enabled when power is
turned on or the return time expires (see next parameter).
Select Knob Return
Time (high tier only)
0-15 seconds in 1-second
steps
Programs the delay after a change is made before the arrow/underline
again indicates the default display mode programmed above. “0” programs
no return (Section 3.4.5).
Radio Has Encryption
Installed
Yes, No “Yes” is programmed if encryption is installed (Section 3.5.7).
Horn Honk Mode Mode A or Mode B Programs the horn alert operating mode (Section 3.5.10).
Radio Can Be Disabled N/A This feature is not available with LTR models of this transceiver.
Radio Can Be
Interrogated
N/A This feature is not available with LTR models of this transceiver.
Status Definitions N/A Status messaging is not available with LTR models of this transceiver.
Digital Volume 0-63 Sets the volume level of data transceivers which do not have an external
volume control. In addition, with low tier models, it sets the initial volume
setting that is selected after programming. “0” selects minimum and “63”
maximum (“20” is default). This is not used with high tier models because
they use an analog volume control to set the volume.
Upload Key Up to eight alphanumeric
characters
If one or more characters are entered, information programmed into the
transceiver cannot be uploaded unless the same characters are re-entered.
If this is left blank, no upload lock is used (see Section 4.5.5).
Penalty TOT 0-60 seconds in 1-second
steps
Programs how long transmitting is inhibited after the time-out timer
disables the transmitter (Section 3.5.16).
Honk Count
(high tier only)
1-8 Programs the number of times the horn alert sounds when it is enabled.
This parameter is fixed at “3” with low tier models (Section 3.5.10).
Horn On/Off Time
(high tier only)
250, 500, 750 ms, 1 sec Programs the on and off times of each horn alert cycle (count). Each time
can be different. With low tier models, the on and off times are both fixed
at 500 ms (Section 3.5.10).
Table 4-1 Main Radio Parameters Screen (Continued)