Service manual

PROGRAMMING
4-19
September 1999
Part No. 001-9800-200
NOTE: Refer to Section 4.6.2 for more information on programming the parameters in the following table.
Table 4-1 Main Radio Parameters Screen
Parameter Available Responses Description
Receive Delay Time 0, 1, 2, 3, 4, 5, 6, or 7
seconds
Time before scanning resumes after a message is received (Section 3.7.3).
Call Delay Time 0, 1, 2, 3, 4, 5, 6, or 7
seconds
Time before scanning resumes after message is transmitted (Section 3.7.3).
Scan Continue Time 0-60 seconds Maximum time that a call is monitored before scanning resumes (Section
3.7.3).
Scan Revert Mode Last Selected, Temporary,
Last Received
Selects the system/group that is selected when the transmitter is keyed in
the scan mode or the scan mode is exited (Section 3.7.4).
Ignition Sense Delay
Time
Immediate, 10, 20, 30, 40,
50 minutes, 1, 2, 4, 8, 10,
12, 16 hours, Forever
Selects the power turn-off delay. If the ignition sense input is not used,
always select “Forever” (Sections 2.4 and 3.5.12).
Conv Proceed to Talk
Tone
Disabled, Enabled Enables or disables the proceed-to-talk tone on conventional systems. It is
always enabled on LTR systems if tones are enabled (Section 3.5.13).
Proceed Tone Type Standard, Loud Selects if a standard or loud proceed tone sounds (Section 3.5.13).
Transmit Time-Out
Time
0.5-5 minutes in 0.5-
minute steps, Off
Programs the Time-Out Timer (Section 3.5.16). See also penalty TOT
which follows.
Mic Hanger Enabled, Disabled When “Disabled” is programmed, taking the microphone off-hook does
not enable the monitor mode or disable system and group scanning.
Display Emergency
(high tier only)
Yes, No When “No” is programmed, the display does not indicate “EMERGNCY”
when the Emergency switch is pressed (Section 3.5.6).