Service manual

OPERATION
3-37
April 2001
Part No. 001-9800-203
Connect the transceiver as described in Section 4
and then press the F7 key from the Main Menu screen.
A screen is then displayed which indicates the infor-
mation in this number. Refer to Section 4.5.1 for more
information on this function.
3.12.4 VIEWING SOFTWARE VERSION
NUMBER
The version number of the operating (Flash) soft-
ware contained in a transceiver can be determined as
follows:
Using Test Mode (High Tier Only)
When the test mode is selected by turning power
on with option switches 2 and 3 pressed (see Section
3.11), the software version number is indicated as
“003x2xx0” on the bottom line of the display. The
breakdown of this number is as follows:
Using Display Test Function (Low Tier Only)
Both low and high tier models have a display test
function that individually enables the various
segments and icons in the display. This display test
function is enabled by turning power on with the
following option switches pressed:
Low Tier Models - A/D and AUX1
High Tier Models - “3” and “5” (see Section 3.11.1).
With low tier models only, in addition to enabling
each segment, the software version number is flashed
by the right-most digit of the display at the end of the
test sequence. After hyphens are indicated by each
display, the display flashes “00312xx0” in sequence. A
breakdown of this number is shown in the preceding
description.
Using Personality Programming Software
With all models including low and high tier and
data, the tier and software version number are
displayed in the lower left corner of the Upload screen
while uploading data. Refer to Section 4.5.5 for more
information.
With data models, this is the only method that can
be used to determine the software version number
since they do not have a display. The tier of these
transceivers is indicated as “DT” (Data Tier).
003x 2xx 0
0030 = High Tier
0031 = Low Tier
0032 = Mid Tier
0033 = Data Tier
Always “0”
Software Version
Number