Service manual
PULL DOWN MENUS
4-8
October 1999
Part No. 001-2009-201
Figure 4-22 RF LINE MONITOR
4.5.4 INPUT MONITOR
The Input Monitor is displayed for analog input
alarms. The screen shows the actual voltage of the
input and the high/low limits. The description of the
alarm entered in the Edit-Alarm Config-Input Alarms
menu as well as the Input Type (Energized, De-Ener-
gized or Analog).
4.5.5 REVISION/VERSION
The Revision/Version is displayed for the
repeater modules in this screen. The format is R.V
(revision.version) for all modules. The MPC informa-
tion also includes the release date of the software and
the serial number of the repeater (see example in
Figure 4-23
).
4.5.6 MODE SELECT
The Mode Select screen places the repeater either
in the Normal mode or the Test mode. In the Normal
mode the repeater operates as a normal repeater.
In the Test mode the repeater transmits a test
word. This test word is the Test Mode ID set up in the
Setup Parameters (see Section 4.3.1
).
C A U T I O N
While in the test mode the repeater is "busy", therefore
it is important to place the repeater in Normal mode
when the test mode is no longer required.
Figure 4-23 REVISION/VERSION
RF Line Monitor
Synthesizer Lock Lines
Exciter Synthesizer: Yes
Receive Synthesizer: Yes
Transmit Parameters
Forward Power: 0 Watts
Reflected Power: 0 Watts
Final Output 1/2: 0/ 0 ratio
Final Output 3/4: 0/ 0 ratio
Receive Parameters
RSSI: 0
System Parameters
Fan 1 Current: 0
Fan 2 Current: 0
Fan On: Off
Chassis Temp: 0 C
Battery Voltage: 0 Volts
Wideband Audio Output: 0
LO Injection: 0
Power Supply Temp: 0 C
(Not Calibrated)
Exciter High Stability: Yes
Receive High Stability: Yes
Repeater Version Display
Serial Number: 1234567891234567
HSDB: 2.1d MAC: 1.09 TIC: 0.00
Repeater Number: 1
MPC or TPI: 10.12 05/23/95 11