Service manual
PULL DOWN MENUS
4-4
October 1999
Part No. 001-2009-201
DATA MODEM
This is selected if the Data Modem option is
installed. This option is not compatible with Paging,
TIC, or VNC options.
4.3.2 SELECT REPEATER
Select the repeater number to be programmed or
edited from the pop-up menu (see Figure 4-6). Move
the cursor with the arrow keys to highlight the
repeater number and press Enter.
Figure 4-6 REPEATER LIST
4.3.3 ALARM CONFIGURATION
This programs the input alarm (see Figure 4-8)
and output alarm (see Figure 4-9) configurations and
provides a cross reference screen.
Figure 4-7 ALARM CONFIGURATION
Use the arrow keys to move down the list. Use
the Space bar to toggle through the parameters: Dis-
abled, Active Low, Active High, for each alarm.
INPUT ALARMS
There are four input alarms that can be activated
by external devices (see Section 6.13). These inputs
can be disabled, energized or de-energized. Alarms 3
and 4 can also be analog input.
Repeater List
default
Rptr 1
-------
-------
-------
Rptr 30
Select Which Alarms To Edit
Input Alarms
Output Alarms
Cross Reference
If the input is disabled, the input alarm line is
inactive. When energized and current flow is
detected, the alarm is activated. When de-energized
and no current flow is detected, the alarm is acti-
vated. Analog inputs provide a detection of an analog
input out of limit condition. Select the Low and High
Limit pair to trip an Analog Input Alarm. The High
Limit must be greater in value than the Low Limit
(0.0V-5.0V in 0.1V steps).
Figure 4-8 INPUT ALARMS
OUTPUT TYPE SELECTION
Selects the operation of the Output Alarm. The
available types are:
Active Open - An active alarm opens (no contact)
the output lines.
Active Closed - An active alarm closes (contact)
the output lines.
Figure 4-9 OUTPUT ALARMS
Input Alarm Configuration
Input Type Selection Description
Spacebar
Door 1 open
Door 2 open
Alarm 1 Input Type: Energized
Alarm 2 Input Type: De-Energized
Alarm 3 Input Type: Analog
Alarm 4 Input Type: Analog
Fuel Tank 1/2
Fuel Tank 1/4
High Limit Voltage (Input3): 2.5 Volts
Low Limit Voltage (Input3): 1.6 Volts
High Limit Voltage (Input4): 1.5 Volts
Low Limit Voltage (Input4): 0 Volts
Description
Spacebar
Output Alarm Configuration
Output Type Selection Tx ID
Alarm 1 Output Type: Active Open
Alarm 2 Output Type: Active Open
Alarm 3 Output Type: Active Open
Alarm Tx Rate: 0
Press F2 to Accept
DOOR OPEN
FUEL 1/2
FUEL 1/4
RF HALF POWERAlarm 4 Output Type: Active Closed
15
120
120
0