Specifications
91
10"
HIGH
VWH
WALL
HOODS
24"W.
30"W.
36"W.
18" HIGH VWH WALL HOODS
24"W.
30" AND 36"W.
42"W.
48" AND 54"W.
60" AND 66"W.
18"
HIGH
ISLAND
VIH
HOODS
36"W.
42"W.
54"W.
66"W.
18"
HIGH
V
CWWH
CHHIMNEY
WALL
HOODS
30" AND 36"W.
42"W.
48" AND 54"W.
60" AND 66"W.
18"
HIGH
VCIIH
CHHIMNEY
ISLAND
HOODS
36"W.
42"W.
54"W.
66"W.
VBCVV
CUUSTOM
VENTILATOR
SYSTEMS
-
FOR
WALL
HOODS
30" AND 36"W.
42"W.
48" AND 54"W.
60" AND 66"W.
2
2
2
2
2
2
3
4
4
4
6
8
2
2
3
4
4
4
6
8
2
3
3
4
VIV300/VIV600/VEV900/VEV1200
VIV300/VIV600/VIV1200/VEV900/VEV1200
VIV600/VIV1200/VEV900/VEV1200
VIV1200/VEV1200/VEV1500
VIV1200/VEV1200/VEV1500
VIV600/VEV900/VEV1200
VIV600/VIV1200/VEV900/VEV1200/VEV1500
VIV1200/VEV1200/VEV1500
VIV1200/VEV1200/VEV1500
DIV300/DIV600/DEV900/DEV1200
DIV600/DEV900/DEV1200
DIV1200/DEV1200/DEV1500
DIV1200/DEV1200/DEV1500
DIV600/DEV900/DEV1200
DIV600/DEV900/DEV1200/DEV1500
DIV1200/DEV1200/DEV1500
DIV1200/DEV1200/DEV1500
VIV300/VIV600/VIV1200/VEV900/VEV1200
VIV600/VIV1200/VEV900/VEV1200
VIV1200/VEV1200/VEV1500
VIV1200/VEV1200/VEV1500
5.6
5.6
5.6
5.0/6.2/8.7/8.7/6.1
5.0/6.2/8.7/8.7/6.1
6.2/8.7/8.7/6.1
11.1/8.4/9.1
11.5/8.8/9.5
4.9/7.4/4.7
4.9/7.4/7.4/4.8/5.5
8.2/5.5/6.2
9.0/6.3/7.1
3.9/6.0/8.7/6.0
6.0/8.7/6.0
11.5/8.5/9.2
11.9/8.9/9.2
3.9/6.6/3.9
4.7/7.4/4.8/5.5
8.6/5.6/6.4
9.5/6.5/7.3
5.0/6.2/8.7/8.7/6.1
6.2/8.7/8.7/6.1
11.1/8.4/9.1
11.5/8.8/9.5
2
2
2
2
2
2
3
4
4
4
6
8
2
2
3
4
4
4
6
8
2
2
3
4
N/A
N/A
N/A
1
1
1
2
2
N/A
N/A
N/A
N/A
1
1
2
2
N/A
N/A
N/A
N/A
1
1
2
2
460 CFM INTERIOR STANDARD MAX. DUCT RUN 50' (15.2 CM)
(7
" ROUND DUCT)
PROPER
INSTALLATION/DUCTTING
IS
EXTREMELY
IMPORTANT
TO
ENSURE
MAXIMUM
PERFORMANCEE
FROM
ANY
VENTILATION
PRODUCTT
•
ALL CFMS STATED BASED ON TESTS WITH .1 STATIC PRESSURE: WITHOUT APPLYING STATIC PRESSURE (SOME BRANDS CONSCIOUSLY
DO NOT), CFM COULD BE GREATLY OVERSTATED.
•
DUCT RUN LENGTH IS FOR GENERAL REFERENCE ONLY; FOR LONGER DUCT RUNS, INCREASE DUCT SIZE AND CONTACT A QUALIFIED AND
TRAINED INSTALLER.
•
STRAIGHT RUNS AND GRADUAL TURNS ARE BEST; FOR EXAMPLE, EACH 90
0
ELBOW IS EQUIVALENT TO 5-10 FEET (1.52-3.05CM) OF
STRAIGHT RUN.
•
NEVER USE FLEXIBLE DUCT; IT CREATES BACK PRESSURE/AIR TURBULENCE AND GREATLY REDUCES PERFORMANCE.
•
PROPER PERFORMANCE IS DEPENDENT UPON PROPER DUCTING; MAKE SURE THAT A QUALIFIED AND TRAINED INSTALLER IS USED.
•
CHECK WITH A QUALIFIED AND TRAINED INSTALLER OR LOCAL CODES FOR MAKEUP AIR REQUIREMENTS, IF ANY.
•
MAX. AMP RATING FOR HOODS INCLUDES RECOMMENDED VENTILATOR KIT RATING; ALL PRODUCTS MUST BE HARD WIRED DIRECT
WITH
2-WIRE WITH GROUND.
•
A 1200 OR 1500 CFM (IF APPLICABLE) VENTILATOR KIT SHOULD BE USED WHEN INSTALLED OVER RANGE/RANGETOPS WITH GAS
CHAR-GRILL.
PROFESSIONAL
HOOD
DATA
DESCRIPTION
FILTERS
RECOMMENDED CFM
120 VAC/60 HZ MAX AMPS
HALOGEN
LIGHTS
HEAT
LAMPS