Specifications

35.76"
Use 5/16" bolt
and flat washer
(included)
Phone Panel Mounting
Rain Guard (included)
Strobe Panel Mounting
Adhere gasket to chassis,
centering over mounting holes
(4) Stainless steel spanner
head screws (bit and
screws included)
42.0"
6.0"
3.12"
1.5"
1.25"
3.0"
3.0"
0.875"
Diameter
0.35"
Diameter
0.35"
Diameter
Front
View
Rear
View
Bottom View
2.87"
1.37"
Knockout for
1/2 inch conduit
Condensation
Drain Hole
Grade 2 Braille Label
"Help" Push to Call Button
Call Connected Red LED
"Info" Push to Call Button
(E-1600A-BLT2-EWP Only)
(4) stainless steel spanner
head screws (included)
Condensation Drain Hole
INFO
HELP
EMERGENCY
PHONE
CALL
CONNECTED
High Visibility
Safety Yellow
Powder Paint
SL-2 Strobe/Beacon
E
M
E
R
G
E
N
C
Y
E
M
E
R
G
E
N
C
Y
Adhere gasket to chassis,
centering over mounting holes
B. Mounting
Step 1.
Mount the tower phone approximately 42” above the floor to a flat, sturdy surface using 5/16 hardware.
Note: Flat washers should be used on the main mounting bolts for additional strength.
Step 2.
Locate the strobe light panel and pass the red and black wires from the strobe panel through the gasket
and the upper hole in the tower.
Step 3. Mount the strobe panel to the tower using the four security screws provided.
Step 4.
Locate the phone panel. Using the gel-filled butt connectors, connect the red and black wires labeled
“Strobe Light” to the red and black wires on the strobe panel.
Step 5. Connect the phone line to the red and green wires (this connection is not polarity sensitive).
Step 6.
Connect the 12V DC adapter wires (-) and (+) to the black with red stripe (-) and red with black stripe (+)
wires from the BLK-4 control module.
Step 7. Mount the phone panel to the tower using the remaining four security screws.