Specifications

B. Entry Code Switches
The blue entry code switches set the relay activation code. This code can make use of any
of the digits available on the rotary switches, as long as the user is aware that D and E can
only be entered using a special 4x4 keypad. Note: For more information on using the RC-
2A with a special 4x4 keypad, retrieve Fax Back Document 855.
A. Security
Rotary
Switch
F
C
B
0...9
Touch
Tone
Ignore
#
,
0...9
Important: In the “Alternative Programming Mode” (DIP switch 5 ON), programming and operation are changed dramati-
cally. Please use the following programming sections only when programming in the “Alternative Programming Mode”. All
“Legacy” Programming and Operation become un-usable and you may ONLY program and operate the RC-2A using the
information provided in the following sections.
A
A
l
l
t
t
e
e
r
r
n
n
a
a
t
t
i
i
v
v
e
e
P
P
r
r
o
o
g
g
r
r
a
a
m
m
m
m
i
i
n
n
g
g
M
M
o
o
d
d
e
e
In the “Alternative Programming Mode” (DIP switch 5 ON), access to the RC-2A is immediate
and it becomes possible to program a one, two or three digit relay activation code. No secu-
rity access code is programmable or required to gain access.
If this DIP switch is in the OFF position, the RC-2A is in the “Legacy Programming Mode”. In the ON position, the
RC-2A is in the “Alternative Programming Mode”.
Switch 5: Selecting Modes
With DIP switch 6 in the OFF position, acknowledgement tones (beeps for relay confirmation, etc.) are turned off.
With DIP switch 6 in the ON position, acknowledgement tones are on.
Switch 6: Relay Acknowledgement Tones
With DIP switch 7 in the OFF position, the automatic phone line answering feature is turned off. With DIP switch
7 in the ON position, the automatic phone line answering feature is turned on. See DIP switch 2 and rotary switch
positions for ring delay (total number of incoming rings before the unit automatically answers the line).
Switch 7: Automatic Answer
This DIP switch is only used in the “Alternative Programming Mode” and has no function in the “Legacy Mode”.
Switch 4: Relay Activation Times
C. Relay Activation Codes
To energize relay (two beeps) ...........................................................................................................................
To de-energize relay (one beep) ........................................................................................................................
To energize relay momentarily (.5 seconds) (one beep).....................................................................................
To energize relay while 4 is pressed and for 1 second after (one beep) .............................................................
To energize relay as long as 5 is pressed (.5 seconds minimum) (one beep).....................................................
To energize relay while 6 is pressed, and 5 seconds after (one beep)................................................................
To interrogate the relay status (two beeps - energized, one beep - de-energized) ............................................
To release the phone line (remote only) (three beeps).......................................................................................
Enter
10
19
13
14
15
16
1#
18 or 8
These activation codes are pre-programmed and cannot be changed except when using the
Alternative Programming mode.
5.