Viking Installation Guide Built-In Gas Rangetops VIKING RANGE CORPORATION 111 Front Street Greenwood, Mississippi 38930 USA
IMPORTANT - PLEASE READ AND FOLLOW •Before beginning, please read these instructions completely and carefully. •Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty. •Please obseve all local and national codes and ordinances. •Please ensure that this product is properly grounded. •The installer should leave these instructions with the consumer who should retain for local inspector’s use and for future reference.
Basic Specifications VGRT Models Description Overall width Overall height 24” W. Models 23 7/8” (60.6 cm) To To To To To top top top top top of of of of of Overall depth from rear Cutout width Cutout Height Cutout Depth Electrical requirements Gas requirements Maximum amp usage Surface burner rating Approximate Shipping Wt. 30” W. Models 29 7/8” (75.8 cm) (Open top Burners only) spider grate 9 1/4” (23.5 cm) (Sealed Burners only) burner grate 9 1/8” (23.2 cm) island trim 8 7/8” (22.
Basic Specifications VGRT Models Description Overall width Overall height Overall depth from rear Cutout width Cutout Height Cutout Depth Electrical requirements Gas requirements Maximum amp usage Surface burner rating Wok Burner rating (If applicable) Griddle burner rating BTU LP Grill burner rating Approximate Shipping Wt. 36” W. Models 42” W. Models 35 7/8” (91.1 cm) To top of spider grate To top of burner grate To top of island trim To top of 6” backguardTo top of high shelf - 42” (106.
Basic Specifications DGRT Models Description Overall width Overall height Overall depth from rear Cutout width Cutout Height Cutout Depth Electrical requirements Gas requirements 30” W. Models To To To To top top top top of of of of 36” W. Models 29 7/8” (759. cm) 35 7/8” (91.1 cm) grate 6 1/8” (15.6 cm) island trim 6 1/8” (15.6 cm) 6” backguard12 1/8” (30.8 cm) high shelf 24 1/8” (61.3 cm) To end of side panel 24 1/2” (62.2 cm) To end of control panel 26 1/8” (66.4 cm) To end of knobs 27 5/8” (70.
GENERAL INFORMATION 1. WARNING:: The use of cabinets for storage above the appliance may result in a potential burn hazard. Combustible items may ignite, metallic items may become hot and cause burns. If a cabinet storage is to be provided the risk can be reduced by installing a rangehood that projects horizontally a minimum of 5” (12.7 cm) beyond the bottom of the cabinets. 2. All openings in the wall behind the appliance and in the floor under the appliance shall be sealed. 3.
Proximity to Side Cabinet Installation 1. This rangetop may be installed directly adjacent to existing 36” (91.4 cm) high base cabinets. IMPORTANT: The top grate support MUST be 3/8” (.95 cm) above the adjacent base cabinet countertop. 2. The rangetop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (91.4 cm) high. There must be a minimum of 6” (15.
WOOD/COMPOSITE OVERLAY INSTALLATION (Including Custom Ventilator Installation) The bottom of any hood should be 30” (68.6 cm) min. to 36” (91.4) max. above the countertop. This would typically result in the bottom of the hood being 66” (167.6 cm) to 72” (182.9 cm) above the floor. Refer to the rangehood installation instructions for additional information. These dimensions provide for safe and efficient operation of the hood.
Gas Connection All gas connections must be made according to national and local codes. This gas supply (service) line must be the same size or greater than the inlet line of the appliance. This rangetop uses an ISO7 or ISO128 inlet. The inlet depends on the end users national and local codes. 1. Manual Shut-off Valve: This installer-supplied valve must be installed in the gas service line ahead of the appliance in the gas stream and in a position where it can be reached quickly in the event of an emergency.
Surface Burner Adjustments (For Open Surface Burners) (See Illustration #2) To gain access to the surface burner adjustments: 1. Remove the grates, burner caps, bowls and grate supports. 2. Located the air shutter (A) and loosen the screw (B) that holds the air shutter in place. 3. Remove the drip tray, allowing you work space to adjust the orifice hood (C). 4. Replace grate support and burner bowls (this allows for correct air flow, as in normal use). 5.
Wok Burner Adjustment To gain access to the burner for adjustments: A 1. Remove the grate and grate support. 2. Locate the air shutter “A” and loosen the two screws “B” that holds the air shutter in place. 3. Light the burner and turn the burner knob to the high position. 4. With a proper, high flame height, adjust the air shutter to obtain a blue flame with no yellow tipping that sits on the burner at the burner ports. (a) open the air shutter gap to add more air and to eliminate yellow tipping.
Grill/Griddle Burner Adjustment 12” Grill Assembly Grill 24” Grill Assembly 1 1. The grill burner orifice and air shutter are located beneath the front end of the grill assembly. To gain access to the adjustment, remove the grill grate, grate support, flavor generators, and the burner shield. 2 2. Remove the screw at the front and rear of the burner. 3. Lift the burner off the orifice and locate the air shutter adjustment 3 screw at the end of the burner. (See Detail “A”) 4.
Initial Ignition of Burners (For Open Surface Burners) All rangetops are tested before leaving the factory. Field adjustments may be necessary for proper mixture of gas and air for proper operation. When the rangetop is connected to gas and electric service, it should be adjusted by a qualified technician. When adjustments are required, contact your dealer/installer for corrections.
WIRING DIAGRAM BUILT-IN GAS DESIGNER RANGETOPS WARNING - Electrical grounding instructions This appliance is equipped with a three-prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded socket. CAUTION - Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. REFER ONLY TO FEATURES WHICH ARE EQUIPPED WITH THIS UNIT.
WIRING DIAGRAM BUILT-IN GAS PROFESSIONAL RANGETOPS VGRT MODELS WARNING - Electrical grounding instructions This appliance is equipped with a three-prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded socket. CAUTION - Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. REFER ONLY TO FEATURES WHICH ARE EQUIPPED WITH THIS UNIT.
Viking Range Corporation 111 Front Street Greenwood, MIssissippi 38930 USA (662) 455-1200 For more product information call 1-888-VIKING1 (845-4641) or visit the Viking web site at vikingrange.