Specifications
12
on
VIKING
©
MODEL K-2000-DVA
VIKING
ELECTRONICS
HUDSON, WI 54016
MULTI-INPUT VOICE
DIALER / ANNOUNCER
INPUTSTELCO PROGRAMMING
RS232
SERIAL PORT
POWER
12 VDC
AUDIO
OUT
ANNOUNCEMENT
VOLUME
VIKING
©
MODEL K-2000-DVA
VIKING
ELECTRONICS
HUDSON, WI 54016
MULTI-INPUT VOICE
DIALER / ANNOUNCER
INPUTS
VOLUME
TELCO
PROG
RS232
SERIAL PORT
POWER
12 VDC
REC
IN
AUDIO
OUT
C.O. Line or Analog
PABX/KSU Station
(Programming
switch = NORM)
* Personal Computer
12V DC
Adapter
Included
120V AC
Vending
Machine
Alarm
Alarm
Alarm
Security Alarm
Temperature
Switch
Nurse Call
Alarm
or
Standard Telephone
(Programming
switch = PROG)
Programming Switch
PROG
For use with a
standard telephone.
NORM
For use with a CO line or
analog PABX/KSU station.
RS-232 9-Pin Straight
Through Cable
(not included)
INPUT 1
COMMON
INPUT 2
INPUT 3
COMMON
INPUT 4
INPUT 8
COMMON
INPUT 7
INPUT 6
COMMON
INPUT 5
** Earth
Ground
Line Level Record Input
600 Ω Audio Output
ON
1 2
Learn Sensitivity
ON
OFF
Normal
Reduced
DIP switch 1 leave OFF.
DIP switch 2 typically left ON.
If false triggers occur because
of very long wire runs to the inputs,
move DIP switch 2 to OFF.
Volume Control
Message Repeat Count: In the Alarm Dialer Mode, this is the number of times the alarm message is repeated per call. In the Storecaster
Mode this is the number of times the message is repeated per closure. In the Storecaster Mode, if the closure is still in effect when the
Message Repeat Count has been met, the K-2000-DVA will reset the message repeat counter and play the message until the Message
Repeat Counter has been met again. The Message Repeat Count is set individually for each input and can be from 1-99.
Pager Number: A phone number of up to 32 digits long which can be used to dial numeric pagers (no alarm message is played).
Priority: Lower number inputs have higher priority.
Qualifier Timer: This is a user-programmable timer that can be set from 1 second to 18 hours and specifies the amount of time that a
closure must stay in effect before the K-2000-DVA enters the alarm state. The default value of the Qualifier Timer is 0, which is OFF.
Remote Access Code: A six-digit code required for remotely accessing the K-2000-DVA in order to poll the alarm inputs for those that
have entered the alarm state and have not been reset.
Reset State: An alarm is reset if the called party or the remotely accessing user dials a touch-tone “9” during the alarm message. The
alarm input resumes normal operation after the Resume Timer expires.
Ring Delay: This is the number of rings the K-2000-DVA waits before answering an inbound call. The Ring Delay must be set from 0-9,
with 0 specifying that incoming calls are not to be answered.
Ringback Limit: This is the number of times the K-2000-DVA will allow the phone to ring when trying to reach a number on its phone
number list before giving up and going on to the next number.
Resume Timer: This is a user-programmable timer that can be set from 1 second to 18 hours and specifies the amount of time after an
alarm input is reset before it resumes normal operation and begins looking for alarms again. See Operation for a discussion of how the
Resume timer determines when an alarm input leaves the reset state. The default value of the Resume Timer is zero, which is OFF.
Security Code: A six-digit code required for entering programming remotely.
Status LED: The Status LED provides a visual indication of operation. When the K-2000-DVA is inactive the LED is ON. In local,
remote, or PC programming the LED is OFF. In the alarm dialer mode, the LED is FLASHING whenever the K-2000-DVA is processing
an alarm. In the store caster mode, the LED is FLASHING while the message is being played.
Storecaster Mode: In this mode the K-2000-DVA plays messages only (no dialing).
I
I
n
n
s
s
t
t
a
a
l
l
l
l
a
a
t
t
i
i
o
o
n
n
A. Alarm Dialer
* IMPORTANT: The computer must have K-2000-DVA(SM) PC programming software installed. Visit www.vikingelectronics.com to download free K-
2000-DVA(SM) programming software. The software is compatible with any Windows based PC, using Windows 98 or higher. The software allows pro-
gramming of all K-2000-DVA parameters using the computer (except the recorded messages for inputs). Viking Electronics will NOT support computer
software or hardware problems. If you experience these problems, research your hardware/software instruction manuals or contact the manufacturer’s
technical support department.
** Note: To increase surge protection, fasten a wire
from the screw terminal to Earth Ground (grounding
rod, water pipe, etc.)
IMPORTANT: Electronic devices are
susceptible to lightning and power
station electrical surges from both the
AC outlet and the telephone line. It is rec-
ommended that a surge protector be
installed to protect against such surges.
Contact Panamax at (800) 472-5555 or
Electronic Specialists Inc. at (800) 225-4876.
!
3
Note: Lower number
inputs have higher
priority.