Specifications

DOOR ENTRY / PAGING
CONTROLLER
VIKING
ELECTRONICS
HUDSON, WI 54016
VIKING
©
MODEL C-1000A
POWER
13.8 V
AC
10 11 12 13 14 15 16 17 18 19
DOOR
STRIKE
1
DOOR
STRIKE
2
DOORB
OX 2
DOORB
OX
PWR OU
TPU
T
DOORB
OX 1
1
EARTH GND
23
PHONE LINE
INPUT
45
LINE OUT
TO PHONES
89
AUX. / DOORBELL
CONTACT OUTPUT
67
KEYLESS CONTACT
CLOSURE INPUT
1
3
2
O
F
F
JP2JP1
C
LED2
C
LED3
N.O. N.C.
N.O. N.C.
TALK BATTERY
OFF ON
OFF ON
C.C
LEARN
MODE
EARTH
GND
C.O. LINE
INPUT
OUT TO
PHONES
KEYLESS
C.C. INPUT
AUX CONTACT
OUTPUT
DOOR
STRIKE 1
DOOR
BOX 1
DOORBOX
13VAC PWR
DOOR
BOX 2
DOOR
STRIKE 2
Doorbell
(not included)
or
Camera
(not included)
Not to Exeed: .5A @ 125V AC
or 1A @ 30V AC
Talk Battery Switch
OFF ON
C.O. Line
or Analog
PABX/KSU
station
Line 1
DOOR ENTRY / PAGING
CONTROLLER
VIKING
ELECTRONICS
HUDSON, WI 54016
VIKING
©
MODEL C-1000A
POWER
13.8 V
AC
10 11 12 13 14 15 16 17 18 19
DOOR
STRIKE 1
DOOR
STRIKE
2
DOORB
OX 2
DOORB
OX
PWR O
UTPUT
DOORB
OX 1
1
EARTH GND
23
PHONE LINE
INPUT
45
LINE OUT
TO PHONES
89
AUX. / DOORBELL
CONTACT OUTPUT
67
KEYLESS CONTACT
CLOSURE INPUT
1
3
2
O
F
F
JP2JP1
C
LED2
C
LED3
N.O. N.C.
N.O. N.C.
TALK BATTERY
OFF ON
OFF ON
C.C
LEARN
MODE
EARTH
GND
C.O. LINE
INPUT
OUT TO
PHONES
KEYLESS
C.C. INPUT
AUX CONTACT
OUTPUT
DOOR
STRIKE 1
DOOR
BOX 1
DOORBOX
13VAC PWR
DOOR
BOX 2
DOOR
STRIKE 2
Line 2
Line 3
Red
Green
Red
Green
C.O. Line
or Analog
PABX/KSU
station
C.O. Line
or Analog
PABX/KSU
station
Fax Machine
or
Answering
Machine
Standard
Analog Phone
13.8V AC
Adapter
included
120V AC
1
3
2
O
F
F
ON
OFF
Earth Ground
(optional)
The C-1000A can be used as a line con-
centrator, allowing up to 3 separate C.O.
lines to connect to one telcom device.
Step 1. Connect as shown to the right.
Step 2. Move DIP switch 3 to the OFF posi-
tion (see Programming section E).
Step 3. Be sure the “Talk Battery Switch
is set to OFF.
Step 4. See Operation section C.
(4)
The C-1000A can also be used without a C.O. line. This is ideal for
connecting the C-1000A to an unused trunk/line input of your phone
system or connecting to phones used only for doorbox communication.
DOOR ENTRY / PAGING
CONTROLLER
VIKING
ELECTRONICS
HUDSON, WI 54016
VIKING
©
MODEL C-1000A
POWER
13.8 V
AC
10 11 12 13 14 15 16 17 18 19
DOOR
STRIKE
1
DOOR
STRIKE
2
DOORB
OX 2
DOORB
OX
PWR OU
TPU
T
DOORB
OX 1
1
EARTH GND
23
PHONE LINE
INPUT
45
LINE OUT
TO PHONES
89
AUX. / DOORBELL
CONTACT OUTPUT
67
KEYLESS CONTACT
CLOSURE INPUT
1
3
2
O
F
F
JP2JP1
C
LED2
C
LED3
N.O. N.C.
N.O. N.C.
TALK BATTERY
OFF ON
OFF ON
C.C
LEARN
MODE
EARTH
GND
C.O. LINE
INPUT
OUT TO
PHONES
KEYLESS
C.C. INPUT
AUX CONTACT
OUTPUT
DOOR
STRIKE 1
DOOR
BOX 1
DOORBOX
13VAC PWR
DOOR
BOX 2
DOOR
STRIKE 2
Talk Battery
Switch
OFF ON
STAND-ALONE
DOOR CONTROLLER
ENTRY SYSTEM
VIKING
PROGRAM
PHONE
GANG
PROG
COMM
ELECTRONICS
HUDSON, WI 54016
VIKING
©
MODEL ES-1
POWER 12 VDC
BLK
RED
GRN
WHT
ENTRY POINT
WIEGAND
DEVICE
LOG
BUS
DOOR ENTRY / PAGING
CONTROLLER
VIKING
ELECTRONICS
HUDSON, WI 54016
VIKING
©
MODEL C-1000A
POWER
13.8 V
AC
10 11 12 13 14 15 16 17 18 19
DOOR
STRIKE
1
DOOR
STRIKE
2
DOORB
OX 2
DOORB
OX
PWR OU
TPU
T
DOORB
OX 1
1
EARTH GND
23
PHONE LINE
INPUT
45
LINE OUT
TO PHONES
89
AUX. / DOORBELL
CONTACT OUTPUT
67
KEYLESS CONTACT
CLOSURE INPUT
1
3
2
O
F
F
JP2JP1
C
LED2
C
LED3
N.O. N.C.
N.O. N.C.
TALK BATTERY
OFF ON
OFF ON
C.C
LEARN
MODE
EARTH
GND
C.O. LINE
INPUT
OUT TO
PHONES
KEYLESS
C.C. INPUT
AUX CONTACT
OUTPUT
DOOR
STRIKE 1
DOOR
BOX 1
DOORBOX
13VAC PWR
DOOR
BOX 2
DOOR
STRIKE 2
Keyed Momentary Switch/
Postal Lock with Limit
Switch (not included)
Viking HID-1
Proximity Card
Reader (not included)
Viking HID-2
Keypad
(not included)
and/or
and/or
D. Using the C-1000A with Keyless Entry, Proximity Card Reader or a Postal Lock Switch
C. Using a C-1000A without a C.O. Line
E. Using the C-1000A to Trigger a Camera or Doorbell
Step 1. Connect the power, required doorboxes, and doorstrike outputs
(if required) as shown in section A.
Step 2. Connect an analog phone or PABX/KSU trunk port to terminals
4 & 5, “LINE OUT TO PHONES” output on the C-1000A.
Step 3. Be sure the “Talk Battery Switch” is in the ON position.
Step 1. Connect a device that can provide a
momentary contact closure, such as
the Viking ES-1 with HID-1 Card
Reader or HID-2 Keypad, keyed
switch, postal lock with limit switch,
etc. to terminals 6 & 7, “KEYLESS
CONTACT CLOSURE INPUT”.
Step 2. Connect doorboxes and doorstrike
outputs (if required) as shown in
section A.
Step 3. See Operation section A, 5. Keyless
Entry/Postal Lock.
Step 1. Connect the camera or doorbell (not included) as shown to
the right. Note: The C-1000A will not supply power to the
camera or doorbell, a power adapter is necessary.
Step 2. Connect doorboxes and doorstrike outputs (if required)
as shown in section A.
Step 3. Program the Auxiliary Contact Output as desired (see
Programming section B).
Step 4. See Operation section A, 6. Auxiliary Contacts.
F. Line Concentrator Mode (One Telcom Device Can Answer up to Three Lines)
?
Need More Information on the HID-1?
Call (715) 386-4345 and select 197.
?
Need More Information on the ES-1?
Call (715) 386-4345 and select 193.
?
Need More Information on the HID-2?
Call (715) 386-4345 and select 199.