VIKING installation instructions and safety information VIKING BLUE ENABLED SOLAR EFFICIENT OPERATION class I, class II, class III, and class IV residential and commercial vehicular swing gate operator
With its compact, low profile design and the power to support 700 lbs of weight along with gate lengths of up to 16 feet, the Viking G-5™ will revolutionize the idea of gate operation. This operator is manufactured with the highest quality components and is designed to accent any gate style. The G-5™ is capable of continuous cycles operation at 24V DC, converted directly from an AC line. The battery back-up provides up to 400 cycles of operation with a maximum capacity gate.
G-5 Vehicular Gate Operator • Revision C3 • November 2009
PARTS PARTS DIAGRAM DIAGRAM 4 5 13 2 10 12 10 16 15 3 6 35 9 34 32 11 8 14 1 7 Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Description Part No.
TABLE TABLE OF OF CONTENTS CONTENTS Parts Diagram/Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i Important Safety Information Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Important Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3 Maintenance/General Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Terminology . . . . . .
IMPORTANT IMPORTANT SAFETY SAFETY INFORMATION INFORMATION WARNING - Not following these instructions may cause severe injury or death to persons. IMPORTANT SAFETY INSTRUCTIONS WARNING – To reduce the risk of severe injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the gate operator monthly.
IMPORTANT IMPORTANT SAFETY SAFETY INFORMATION INFORMATION WARNING - Not following these instructions may cause severe injury or death to persons. IMPORTANT INSTALLATION INSTRUCTIONS Continued 6. Controls intended for user activation must be located at least six feet (6’) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls.
IMPORTANT IMPORTANT SAFETY SAFETY INFORMATION INFORMATION WARNING - Not following these instructions may cause severe injury or death to persons. MAINTENANCE Remove the Power Harness from the Control Board (refer to page 17) • Clean and lubricate the turning pins and gate hinges using the recommended lubricant. • Clean and lubricate the lead screw using silicon grease. • Check that all mounting hardware of the gate operator is properly tighten. • Ensure that the gate moves freely.
IMPORTANT IMPORTANT SAFETY SAFETY INFORMATION INFORMATION CAUTION: To Reduce the Risk of Fire or Injury to Persons a) Use only the following type and size of battery(ies): Yuasa NP7-12 b) Do not dispose of the battery(ies) in fire. The cells may explode. Check with local codes for possible disposal instructions. c) Do not open or mutalate the battery(ies). Released electrolyte is corrosive and may cause damage to the eyes or skin. It may be toxic fi swallowed.
Radio Rec. Reopen Loop Center Loop Sensor Obstruction Center Safety UL Radio IMPORTANT IMPORTANT SAFETY SAFETY INFORMATION INFORMATION Loop Loop Sensor Rec. Sensor UL Sens Obstruction ay Charger Power WARNING - Not following these instructions may cause severe injury or death Low to persons. Battery MAX- This type of installation DOES NOT reverse the gate all the way back to its limits Motor Check Motor NOTE whenSensor the photo-beam is obstructed.
Obst 0 3 Low Battery min. Motor Sensor Check Motor MAX Hold Open Timer IMPORTANT IMPORTANT SAFETY SAFETY INFORMATION INFORMATION Mag. Lock WARNING - Not following these instructions may cause severe injury or death to persons. Open Mag. LOCK Lock MAG. Stop Mag. Lock 30 Stop Open Hold Open Timer COM N.O.
IMPORTANT IMPORTANT SAFETY SAFETY INFORMATION INFORMATION WARNING - Not following these instructions may cause severe injury or death to persons. Audible Alarm Reset Switch Installation Manual Reset for the Audible Alarm UL325 standard requires an audibleJP3alarm to go off after two consecutive events detected by the primary entrapment protection of the gate operator (obstruction sensor). The audible alarm will continue to sound for 5 minutes or until a stop command C35 C36 gets actuated. Obstruction 1.
IMPORTANT IMPORTANT INSTALLATION INSTALLATION INFORMATION INFORMATION CAUTION - FOR USE WITH GATES OF A MAXIMUM OF 16 FT IN LENGTH AND 700 LBS. IN WEIGHT. WARNING - TO REDUCE THE RISK OF SEVERE INJURY OR DEATH TO PERSONS: This is NOT a pedestrian gate operator Do NOT Install the gate operator to lift gates 16'-0" OPEN STOP CLOSE Control Buttons Button s Locate Control Buttons: 16’ maximum gate length 1. Within sight of the gate, 2.
PLAN PLAN OF OF INSTALLATION INSTALLATION -- OPEN OPEN INSIDE INSIDE The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.
PLAN PLAN OF OF INSTALLATION INSTALLATION –– OPEN OPEN OUTSIDE OUTSIDE The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.
GATE GATE OPERATOR OPERATOR INSTALLATION INSTALLATION CAUTION - If Front Mounting Bar is not welded to a frame member that runs the full length of the gate, the gate operator may damage the gate. Do not weld the bar or backing plate to a few pickets. STEP 1 Cut the Front Mounting Bar (the offset bar) so that: The bolt center is 4-3/4” from the inside surface of the gate and 27” to 28” from the gate hinge. Note: It is recommended to use a frame member across the full width of the gate.
GATE GATE OPERATOR OPERATOR INSTALLATION INSTALLATION Step 3 Remove the Terminal Cover: a) Open the plastic flap and b) Remove the Thumbscrew. STEP 4 Mount the operator. Perform the Manual Release procedure as shown at the bottom of page 7. The gate can now be moved manually. Ensure that the gate and gate operator moves freely. Check Operation Through Entire Range of Movment Once it is determined the operator will work properly, remove the operator and complete the welding process.
GATE GATE OPERATOR OPERATOR INSTALLATION INSTALLATION Limit Switch Setup STEP 6 Pull Cover Forward and Remove Remove the lead screw cover: a) Remove the screw and b) Slide out the cover. Adjust the Limit Switches STEP 7 Note: Leave cover off until after the installation of the control box and the electrical installation. Verify that the operator opens and closes to the desired position under power. Make any adjustments as necessary.
GATE GATE OPERATOR OPERATOR INSTALLATION INSTALLATION Opening/Closing Setup: To have the gate operator slow down prior to reaching its limits use the following steps: 1. Setup the Limit Switches manually at the desired open and close position. 2. Allow the gate operator to run a full open and close cycle (from limit to limit) without interruption. Note: During the first full open and close cycle: The gate operator doesn’t slow down prior to reaching its limits.
CONTROL CONTROL BOX BOX INSTALLATION INSTALLATION WARNING - If the control box is not mounted properly it may fall, causing damage and/or injury. The Electronic Control Unit (ECU) weight is approximately 40 lbs. Be sure that the substrate being mounted to and the fasteners being used are appropriate to support the weight of the control box. 1. Disconnect the Siren and Stop Button Leads from the Control Board. Remove the Control Board Mounting Plate. The plate is held in the box by four screws. 17" 2.
ELECTRICAL ELECTRICAL INSTALLATION INSTALLATION Caution – Do not connect the power harness to the board until the installation is ready for verification. Power Harness The G-5 Gate Operator requires a single phase AC line to operate and charge the batteries. 1. Turn off the main switch or breaker for the power line being used. 2. Move the selector switch on the Incoming Voltage Selector to the proper position (115 for 110 to 120VAC, 230 for 200 to 240VAC). 3.
ELECTRICAL ELECTRICAL INSTALLATION INSTALLATION –– SINGLE SINGLE UNIT UNIT Single Unit Connections Connect the wires from the motor unit to the terminal block mounted next to the control board. Match wire colors to the terminal block. Open Obstruction Overlap Delay Center Loop Sensor Sensor 1.5 Gate opens outside 1.5 Sensor Sensor N.O. COM N.C. +28v Gnd UL Radio Gate opens Sensor Rec.
ELECTRICAL ELECTRICAL INSTALLATION INSTALLATION –– MASTER/SLAVE MASTER/SLAVE Master/Slave Connections A Master/Slave control board is available, when required, to run two gate operators in synchronous mode. Slave Limit Open Limit Close Slave Limit Open Limit Close Obstruction Overlap Delay Center Loop Sensor Safety Loop UL Sensor Radio Rec.
de VEHICULAR VEHICULAR LOOP LOOP DETECTOR DETECTOR INSTALLATION INSTALLATION O ut si op e tsid en Lo u O eop R op r Lo e t n Ce oop id Ins e nL ope e R Loo p In si de t Exi Note: Not all loops may be necessary for every installation. Check local regulations and accepted bestpractice design requirements.
VEHICULAR VEHICULAR LOOP LOOP DETECTOR DETECTOR INSTALLATION INSTALLATION WARNING – Consult the installation instructions from the loop detector manufacturer. The following statements are provided as a guide but different requirements may be required by the vehicular loop detector manufacturer. Guidelines for Vehicular Loop Detector Installation 1. Prevent sharp corners in the geometry of the loop sensor. 2. Install the appropriate number of turns for your loop geometry based on the loop perimeter.
UL Sens Reopen Loop OPEN LEFT Mag. Lock Mag. LOCK Lock MAG. UL Sens As an alternative to the Outside Reopen Loop, N.O. a photo beam unit can be used as shown. +28v Gnd Photo Beam TECHNICAL SUPPORT 1 800 908 0884 +28v Gnd UL Gnd Mag. Lock Mag. LOCK Lock MAG. N.O. +28v Gnd +28v Radio Gnd +28v N.C. +28v Radio Gnd +28v Photo Beam COM Inside N.C. COM Radio Station Gnd UL Gnd Reopen Gnd Center Gnd Edge Sensor Outside 22 Mag.
ACCESSORY ACCESSORY CONNECTIONS CONNECTIONS 24VAC Radio Receiver When connecting the Radio Receiver carefully verify the proper connections. 24V BAT Fail Safe/Secure The maximum voltage that the control board provides for external accessories is the maximum voltage of the battery, which is about 28 volts.
M-2 ™ VIKING VIKING ELECTROMAGNETIC ELECTROMAGNETIC LOCK LOCK Standard Features Mounting base with electrical box Mounting Plate/Juction Box (Weld to Post) 24VDC Plug-in transformer Magnetic Lock 12VDC or 24VDC operation Mounting Screw (4) 500mA at 12VDC operation Mounting Screw Weather Cover (4) 250mA at 24VDC operation 1300 pounds of holding force Floating Plate • • • • • • Guide Pin (2) Use long or short pin depending on number of spacers used Flexible Washer Mounting Plate Floating Plate Magneti
OPEN RIG 24VAC Magnetic Lock Off 1 +28v Gnd min. Hold Open Timer 2 N.O. N.O. N.O. OPEN STOP CLOSE COM 24 TECHNICAL SUPPORT 1 800 908 0884 25 Saf Loo Gnd Gnd Exit Gnd Strike Gnd Gnd Fire Open Commands Open Stop Close GND Open Stop Guard Station Center Off 1 30 Open 60 Place the control switch box within sight of the gate, away from moving parts of the gate and out of reach of children.
SPECIAL SPECIAL FEATURES FEATURES Intelligent Obstruction Sensor (Primary Entrapment Protection) 0 Center Loop Sensor Obstruction Safety Loop Se MAX Hold Open Timer Turning the Trim Pot clockwise increases the sensitivity. Hold Open Open Turning the Trim Pot counterTimer clockwise decreases the sensitivity. Open 60 1. Stop the gate’s movement and reverse it momentarily. Off 1 Stop Close Center Loop Sensor min.
SPECIAL SPECIAL FEATURES FEATURES Fail Safe/Fail Secure Operation 1 The gate operator contains a unique design that allows the user to move the gate manually in case of power failure. There are three levels of force required to move the gate manually. 24V BAT Fail Safe/Secure Minimum Force: By removing the wire-jumper plug from the “Fail Safe/Secure” connector: The gate can be move manually with relative low amount of force. 1 Radio Rec. Radio Rec. 0 Check Motor Motor Sensor Mag. Lock Mag.
SPECIAL SPECIAL FEATURES FEATURES Gate Overlap Setting Setting the Overlap Delay Pot to “0” will cause the master and the slave units to open and close at the same time A Master/Slave control board is required to operate two gates with a single controller. Obstruction Overlap Delay Center Loop Sensor 1.
SPECIAL SPECIAL FEATURES FEATURES Auto-Open Feature 0 UL Sens N.C. N.O. +28v 29 Gnd +28v Ra Gnd UL Gnd Reopen Gnd Center Gnd Safety Loop Connector Connector COM Gnd Radio Rec. Reopen Loop Off 1 Exit Gnd Strike Gnd Fire Open Commands Gnd Open Stop Close Guard Station GND Open Stop Close GND Master/Slave Siren Mag. Lock Mag. LOCK Lock MAG. +28v Radio Gnd +28v Radio Rec.
Safety Loop Connector Connector Radio Station N.O. COM N.C. Mag. Lock Mag. Lock Connect the Solar Panel Controller as shown. Check Motor Motor Sensor Low Battery Power Charger – + – Remove existing batteries. Use new external batteries of 35 AHr or greater and connect them in series to provide a 24V system. 30 TECHNICAL SUPPORT 1 800 908 0884 24VAC + Fail Safe/Secure 24V BAT Remove the existing Power Harness and use the power harness provided. Radio Rec.
ector ctor Radio Station Mag. LOCK Lock MAG. N.O. COM N.C. Mag. Lock OPTIONAL OPTIONALSOLAR SOLAR PANEL PANEL INSTALLATION INSTALLATION Mag. Lock For Viking Vehicular Gate Operators Check Motor Motor Sensor WARNING – Solar Panel must be UL Listed, Class 2 Low Battery Power Charger il ecure Replace the existing batteries with a battery pack of 35AHr or greater.
VIKING VIKING PIPE PIPE STAND STAND Part No. VA-G5PSKT For Viking G-5 Vehicular Gate Operator Standard Features • Main pieces made of 1/4” thick material • All hardware included When installing the Pipe Stand Assembly be sure it is parallel to the gate and that it is level. For further details see the G-5 installation manual. Grade Level Consult Local Codes for Depth and Concrete Requirements 3-1/2" Pipe (4.
PLAN PLAN OF OF INSTALLATION INSTALLATION -- OPEN OPEN INSIDE INSIDE The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas. Outside Gate in Closed Position C B E A D Gate in Open Position Inside 90°/ 120° 6" Square Pipe 4" Square Pipe Open Left 3-1/2" (4.
L G nd Ex it St rik e ds an m om C nd G O nd G n pe O Fi re 60 30 O pe n D n io at St rd ua G N X A G M e lo s e av Sl r/ ts e a M lo C se 36 C 3 C 35 n ak e m . in Radio Rec. JP Power Mag. LOCK Lock MAG. Mag. Lock N.C. COM N.O. +28v Gnd +28v Radio Radio Station If you are using the computer: • Hold the computer near the Gate Operator. • Run the application by clicking the icon on the desktop. • Select “Setting” in the top right of the screen.
TROUBLESHOOTING TROUBLESHOOTING Gate does not run – Motor Sensor indicator comes ON Check all motor connections to be fully engaged. Refer to page 15, 18 and 19. Ensure that the motor connections are: a) Properly connected, b) Tight enough and c) Color coded Refer to page 15. Check that all motor cable connections, junctions and extensions are properly connected and color-coded. Refer to page 15.
TROUBLESHOOTING TROUBLESHOOTING Gate does not open or close Check all motor connections to be fully engaged. Refer to page 15. Check that limit switches are connected to the common and the normally close position refer to page 15. Check that the stop command is not active. Refer to page 8 and 25. Check that the UL command (photo beam and/or edge sensor) is not active. Refer to page 6, 7 and 22. Check that the vehicular loop detectors are working properly. Refer to page 20, 21 and 22.
TROUBLESHOOTING TROUBLESHOOTING Gate opens after few second delay Set the overlap delay trim pot to 0. Refer to page 28. Note: Overlap trim pot is normally recommended to use in overlapping gates. Refer to page 28. Gate opens. Closes or stops on its own Ensure that the key for manual release is in the lock position. Refer to page 7. Make sure that the ‘Charger’ LED is on, indicating that there is AC power. G-5 unit runs slower than normal Set the overlap delay trim pot to 0. Refer to page 28.
Notes
our continuous commitment to excellence Viking Access Systems is continuously working hard to identify and design products that will appeal to the industry and it’s needs. As technology continues to advance, we have developed a completely efficient and intelligent line of gate operators to meet the changing demands. These machines offer; full UL325 and UL991 compliance, soft-start and soft-stop, intelligent obstruction sensors, continuous operation (100% duty cycle) and extreme power efficiency.
VIKING standard features and operator specifications UL325 and UL991 Listed by Underwriter Laboratories (UL) • Accessible manual release via key operated mechanism • Fail-Safe option sets the gate to automatically transfer to a fail-safe mode in the event of a power failure, allowing the gate to be pushed open without the use of special knowledge of the equipment • FailSecure option sets the gate to mechanically lock in the event of a power failure, allowing no manual movement without the use of the manua