Product manual
12
Quick Programming Features (after accessing the Programming Mode)
DESCRIPTION
ENTER
DIGITS
+
MEMORY
LOCATION
First emergency speed dial number 0-20 digits + #00
Second emergency speed dial number 0-20 digits + #01
Third emergency speed dial number 0-20 digits + #02
Fourth emergency speed dial number 0-20 digits + #03
Fifth emergency speed dial number 0-20 digits + #04
First “Info” speed dial number (E-1600-20/22/52/53-IP only) 0-20 digits + #05
Second “Info” speed dial number (E-1600-20/22/52/53-IP only) 0-20 digits + #06
Third “Info” speed dial number (E-1600-20/22/52/53-IP only) 0-20 digits + #07
Fourth “Info” speed dial number (E-1600-20/22/52/53-IP only) 0-20 digits + #08
Fifth “Info” speed dial number (E-1600-20/22/52/53-IP only) 0-20 digits + #09
To clear any speed dial number (no digits) + #00 - #09
Talk/Listen Delay (.1 to .9 sec, factory set to .2 sec) 1 digit (1-9) + #11
Call Length Time Out (0 to 9 min, 0 = disabled, factory set to 3 min) 1 digit (0-9) + #12
Message Play Count (0 to 9, 0 = play every 8 sec, factory set to 1) 1 digit (0-9) + #15
Lap Counter (0 to 9, 0 = disabled, factory set to 0) 1 digit (0-9) + #16
Dial Next Number on Ring No Answer (0 or 1 = disabled, 2 - 9 = number
of rings, factory set to 7)
1 digit (0-9) + #17
Dial Next Number on Busy (1 or 2, 1 = disabled, factory set to 2/enabled) 1 digit (1 or 2) + #18
Security code (factory set to 845464) 6 digits (0-9) + #19
Identification number (factory set to 987654) 6 digits (0-9) + #20
Access Code (six digits, factory set to 123456) 6 digits (0-9) + #21
Mic volume (0-9, 0 = ANC, factory set to 5) 1 digit (0-9) + #22
Speaker Volume (0-9, factory set to 5) 1 digit (0-9) + #23
Relay Activation Command ( 1 or 2 digits, QQ = Q, QQQQ = QQ, 0-9 or
00-99, factory set to QQ) (Relay Mode must be set to 0 = Door Strike)
1 or 2 digits + #24
Relay Activation Time (2 digits, 00-99 sec, 00= 0.5 sec, factory set to 05) 2 digits (00-99) + #25
Relay Mode (0 = Door Strike, 1 = Phone Active, 2 = Door Bell,
3 = LV-1K Control, factory set to 0)
1 digit (0-3) + #26
Relay Activation Tone (Buzz) Volume (1 digit 0-3, 0 = off, factory set to 3) 1 digit (0-3) + #27
DESCRIPTION ENTER DIGITS
Diagnostic tones (used to check mic and speaker operation)
Q0
Enable Alternate Switch Action (factory setting)
Q1
Disable Alternate switch Action
Q2
Erase Message
Q3
Record Message (enter # to stop recording)
Q4
Playback Message
Q5
Enable Latching Commands (factory setting)
Q6
Disable Latching Commands
Q7
Enable Auto Answer (Factory Setting)
Q8
Disable Auto Answer
Q9
To add a Q at any point in the dialing string
QQ
To add a # at any point in the dialing string
Q#
Reset all Quick Programming Features to factory default settings ###
Exit programming and disconnect ##7