Viking Installation Guide Designer DGVU Built-In Gas Cooktops
Table of Contents Warnings & Important Safety Instructions _______________________________________________3 Dimensions (30”) ____________________________________________________________________6 Dimensions (36”) ____________________________________________________________________7 Specifications _______________________________________________________________________8 Cutout Dimensions __________________________________________________________________9 Downdraft Dimensions ___________________________________
IMPORTANT– Please Read and Follow • Before beginning, read these instructions thoroughly and carefully. Your safety and the safety of others is very important. We have provided many important safety messages in this manual and on your appliance. ALWAYS read and obey all safety messages. • Installation and service must be performed by a qualified installer, service agency, or the gas supplier. • DO NOT remove permanently affixed labels, warnings, or plates from the product as this may void the warranty.
IMPORTANT– Please Read and Follow DANGER WARNING FIRE/EXPLOSION HAZARD CHEMICAL HAZARD If not installed, operated and maintained in accordance with the manufacturer’s instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness and which are known to cause cancer, birth defects, or other reproductive harm.
IMPORTANT– Please Read and Follow WARNING ELECTRICAL GROUNDING INSTRUCTIONS The cooktop must be electrically grounded in accordance with local codes or, in the absence of codes, with the ANSI/NFPA No. 70-latest edition. Installation should be made by a licensed electrician. This appliance is equipped with a three-prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle. DO NOT cut or remove the grounding prong from the plug.
Dimensions 30” Gas Cooktop 30-3/4” (78.2 cm) 21” (53.4 cm) 2-13/16” (7.1 cm) 4” (10.2 cm) 7-3/16” (18.4 cm) 28-1/8” (71.4 cm) Wiring diagram and rating plate location 18-1/4” (47.0 cm) Power cord 6 Regulator 2” (5.1 cm) 10-3/16” 2” (27.1 cm) (5.
Dimensions 36” Gas Cooktop 36-3/4” (93.3 cm) 21” (53.4 cm) 2-13/16” (7.1 cm) 4” (10.2 cm) 7-3/16” (18.3 cm) 34-1/8” (86.6 cm) Wiring diagram and rating plate location 18-1/4” (47.0 cm) Power cord 7 Regulator 2” (5.1 cm) 10-3/16” 2” (27.1 cm) (5.
Specifications Designer Gas Cooktops Description DGVU200 DGVU260 Overall width 30-3/4” (78.1 cm) 36-3/4” (93.3 cm) Overall height from bottom to top of grate 4” (10.2 cm) Overall depth from rear 21” (53.3 cm) Cutout width 28-1/2” (72.4 cm) min. to 29” (73.6 cm) max. 34-1/2” (87.6 cm) min. to 35” (88.9 cm) max. Cutout height 2-13/16” (7.1 cm) Cutout depth 19” (48.3 cm) min. to 19-5/8” (49.8 cm) Gas requirements Accepts standard residential ½” (1.3 cm) I. D. gas service line.
Cutout Dimensions B A C C DGVU200 DGVU260 A 28-1/2” (72.4 cm) min. to 34-1/2” (87.6 cm) min. to 29” (73.6 cm) max. 35” (88.9 cm) max. B 19” (48.3 cm) min. to 19-5/8” (49.8 cm) 2-1/2” (6.4 cm) C Note: Based on 24” deep cabinet with 3/4” backsplash. Downdraft Dimensions E F D C A B C B D DGVU260 29-1/8” (74.0 cm) 34-7/8” (88.6 cm) 20-5/8” (52.3 cm) 27 (68.6 cm) 33” (84.0 cm) 2-1/4” (5.7 cm) E 1-1/16” (1.1 cm) 15/16” (1.0 cm) F 1-1/16” (1.1 cm) 15/16” (1.
Clearance Dimensions Proximity to Side Cabinet Installation (Proximity to Cabinets) Minimum Clearances from Adjacent Combustible Construction • The cooktop may be installed directly to existing base cabinets. • The cooktop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (91.4 cm) high. There must be a minimum of 5” (12.7 cm) side clearance from the cooktop to such combustible surfaces above the 36” (91.4 cm) counter height.
Clearance Dimensions The bottom of a standard hood should be 30” (76.2 cm) min. to 36” (91.4 cm) max. above the countertop. This would typically result in the bottom of the hood being 66” (167.6 cm) to 72” (182.9 cm) above the floor. These dimensions provide for safe and efficient operation of the hood. Refer to the rangehood installation instructions for additional information. (Wood/Composite or Steel Overlay) Wo o or d/Co Ste mp el O os ver ite l ay 66 (16 ”mi 7.6 n. c to m) 72 (18 ”ma 2.9 x.
Electrical & Gas Requirements Electrical Requirements There is no connection necessary beyond plugging the unit into a polarized, grounded, 120 volt, 60 Hz, 15 amp circuit. A minimum of 120 VAC is required for proper operation of gas ignition systems. DO NOT use a GFI circuit. This circuit, however, MUST be grounded and properly polarized. The unit is equipped with 16-3 SPT2 power cord.
Electrical & Gas Requirements Rigid Connections (cont.) Initial Ignition of Burners • Installer-supplied intake pipes should be checked visually for any foreign matter before installing in a service line. • All cooktops are tested before leaving the factory. Field adjustments may be necessary for proper mixture of gas and air for proper operation. Contact a qualified technician to make any necessary adjustments. • The surface burners use electric igniters in place of standing pilots.
General Information • Upon ignition of the surface burner, turn the knob to the desired position (HI, Med or Low). • To shutdown the burner, turn knob clockwise to the OFF position. • In case of failure, shut the gas OFF using the installer supplied manual shut-off valve. CAUTION ELECTRICAL SHOCK HAZARD Plug into a 3 prong outlet. DO NOT remove ground prong. DO NOT use an adapter. DO NOT use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock.
Installation 1 2 1 2 1 2 2 2 Remove the grates and burner caps. 3 Turn the cooktop upside down and place on the packaged foam top. Note: Make sure there are no loose objects on the cooktop before turning upside down. 4 Optional Gasket Turn the cooktop over and place into countertop opening. Peel away the plastic covering and place the gasket material all the way around the burner flange. IMPORTANT: Make sure the corners are covered completely, leaving no air gaps.
LP Conversion 1 WARNING LP conversion should only be performed by a qualified service technician Remove aluminum gas spreaders. 3 2 2 2 60 105 115 90 2 90 2 1 60 105 115 105 Reference chart to determine which injectors are needed for each burner. Remove injectors using a 9/32” nut driver. 5 4 1 1 1 1 2 Replace aluminum flame spreaders. Install and tighten injectors.
LP Pressure Regulator Conversion 1 2 2 1 Disconnect electrical power and shut off gas. Unscrew regulator cap. 4 3 2 4 1 5 1 3 2 Unscrew the plastic conversion plug from the cap and turn over. Screw plug back into cap with the wide section away from cap. Replace regulator cap. 5 Test gas pressure. When converting the regulator for different settings, the function of the regulator must be checked at a pressure at least 1” WC (249Pa) above the specified manifold pressure.
Gas & Electrical Connection Bracket Installation 1 1 Note: Refer to “Electrical & Gas Requirements” section for proper installation information. Countertop Cooktop Bracket Place brackets in the slots and lower until the bracket catches. Use the bolt to tighten the cooktop to the countertop. Note: There must be a 1” (2.5 cm) clearance under counter on all four sides of cooktop.
Final Preparation • New units are cleaned at the factory to remove any visible signs of dirt, oil, grease, etc. remaining from the manufacturing process. Some stainless steel parts may have a plastic protective wrapper which must be peeled off. The cooktop should be washed thoroughly with hot, soapy water and then rinsed and wiped dry to remove these film residues and any installation dust or debris before being used for food preparation.
Service & Registration Only authorized replacement parts may be used in performing service on the appliance. All servicing should be referred to a qualified technician. Contact Viking Range Corporation, 1-888-VIKING1 (845-4641), for the nearest service parts distributor in your area or write to: VIKING RANGE CORPORATION PREFERRED SERVICE 1803 Hwy 82W Greenwood, Mississippi 38930 USA The serial number and model number for your appliance can be found by looking under the cooktop.
Notes ________________________________________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________________________________________ ____________________________________________
Notes ________________________________________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________________________________________ ____________________________________________
Notes ________________________________________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________________________________________ ____________________________________________
® Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.