Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.
IMPORTANT: PLEASE READ AND FOLLOW BASIC SPECIFICATIONS 1. 2. 3. 4. 5. DESCRIPTION VGSU103 (30” W.) VGSU163 (36” W.) Cutout Width - Minimum Maximum Cutout Height - Minimum Cutout Depth - Minimum Maximum Overall Width Overall Height from Bottom Overall Depth from Rear Gas Requirements 26-7/8” (68.3 cm) 29-7/8” (75.9 cm) 34-3/8” (87.3 cm) 35-7/8” (91.1 cm) Before beginning, please read these instructions completely and carefully.
DESCRIPTION DGSU100 (30” W.) DGSU160 (36” W.) PROXIMITY TO SIDE CABINETS Cutout Width - Minimum Maximum Cutout Height - Minimum Cutout Depth - Minimum Maximum Overall Width Overall Height from Bottom Overall Depth from Rear Gas Requirements 29-1/8” (74.0 cm) 29-7/8” (75.9 cm) 34-7/8” (88.6 cm) 35-7/8” (91.1 cm) 1. The cooktop may be installed directly to existing base cabinets. 2.
CUTOUT DIMENSIONS FOR VGSU AND DOWNDRAFT WOOD/COMPOSITE OVERLAY INSTALLATION The bottom of the hood should be 30” (76.2 cm) min. to 36” (91.4 cm) above the countertop.This would typically result in the bottom of the hood being 66” (167.6 cm) to 72” (182.9 cm) above the floor. Refer to the rangehood installation instructions for further information. These dimensions provide for safe and efficient operation of the hood.
VGSU Height Dimension DIMENSIONS FOR INSTALLATION OF VGSU OVER SINGLE ELECTRIC OVEN 3” (7.6 cm) min. 5” (12.7 cm) 18-5/8” (47.3 cm) 6-19/32” (16.7 cm) 2-1/2” (6.4 cm) 26-7/8” (73.3 cm) 14-1/4” (36.2 cm) 28-1/8” (71.4 cm) 30” W. VGSU Top Dimensions 14-5/8” 16-7/8” (42.9 cm) 17” (31.1 cm) CL (37.2 cm) 1” (2.5 cm) 14-1/4” (36.2 cm) VESO130/530 30” min. cutout 3” (7.6 cm) min. VGSU163 36” min. cutout VGSU103 30” min. cutout 12-1/4” 13/16” (2.1 cm) 34-3/8” (87.3 cm) (43.
30” W. DGCU Top Dimensions DGCU CUTOUT DIMENSIONS Cutout Opening 21“ (53.3 cm) 19-3/4” (50.2 cm) B Min. 30” W. 36” W. B 45” W. Max. 28-3/4” (73.0 cm) 34-1/2” (87.6 cm) 42-7/8” (108.9 cm) 29-7/8” (75.9 cm) 35-7/8” (91.1 cm 44-1/8” (112.1 cm) 30-3/4” (78.1 cm) DGCU Burner Box Dimensions 1” (2.5 cm) 36” W. DGCU Top Dimensions 1-1/4” (3.2 cm) 19-11/16” (50.0 cm) Electric Cord 48” (121.9 cm) Gas Inlet 21“ (53.3 cm) 30” W. Model 28-3/4” (73.0 cm) 36” W. Model 34-1/2” (87.6 cm) 45” W.
DGSU CUTOUT DIMENSIONS 30” W. DGSU TOP AND HEIGHT DIMENSIONS 21“ (53.3 cm) 19-3/4” (50.2 cm) Minimum 20-1/8” (51.1 cm) Maximum Cutout Opening 30-3/4” (78.1 cm) C C Min. 29-1/8” (74.0 cm) 34-7/8” (88.6 cm) 30” W. 36” W. 4-3/8” (13.7 cm) 3-1/8” (7.9 cm) Max. 29-7/8” (75.9 cm) 35-7/8” (91.1 cm) 1-3/4” (4.5 cm) 36” W. DGSU TOP AND HEIGHT DIMENSIONS DGSU BURNER BOX DIMENSIONS 3-1/16” (7.8 cm) 1-1/16” (2.7 cm) 1-1/16” (2.7 cm) 19-3/4” (50.2 cm) Electric Cord 48” (121.9 cm) 30” W. Model 29-1/8” (74.
GAS CONNECTION INSTALLATION OF HOLD DOWN BRACKET FOR DGCU AND DGSU MODELS Top of cooktop Two (2) hold brackets will be provided with the DGSU models and (4) hold brackets will be provided with the DGCU models. After cooktop has been installed into the countertop, locate the brackets in the slots as needed (Figure 1). Place a bracket in the slots and lower until the bracket catches. (Figure 2). Use the bolt to tighten the cooktop to the countertop.
ELECTRICAL CONNECTION There is no connection necessary beyond plugging the unit into a polarized, grounded, 120 volt, 60 Hz, 15 amp circuit. A minimum of 120VAC is required for proper operation of gas ignition systems. DO NOT USE a GFI circuit. This circuit, however, MUST be grounded and properly polarized. The unit is equipped with 16-3 SPT2 power cord, and if an extension is required, it must be of at least this gauge.