Specifications

TECHNICAL SUPPORT 1 800 908 0884
17
The Gate Operator requires a single phase AC
line to operate the gate and charge the batteries.
1. Turn off the main switch or breaker for
the power line being used.
2. Move the selector switch on the Incoming
Voltage Selector to the proper position
(115 for 110 to 120VAC, 230 for 200 to 240VAC).
3. Connect the incoming power wires to the
terminals as shown in the illustration.
4. Turn on the main switch or breaker once
the installation is ready for final
adjustments.
ELECTRICAL INSTALLATIONELECTRICAL INSTALLATION
To
Transformer
Hot
Power Ground
115/220
Power Switch
Earth Ground
Neutral
Tips for proper ground installation
A good ground in a gate operator
installation will minimize or prevent damage
to the operator cause by natural events such
as lightning strikes.
The following will provide a guideline for
proper grounding:
1. Use a ground rod to provide a ground
reference.
2. Consult your city code and be aware of
under-ground services in the site of the
gate operator to prevent inconveniences.
3. Use always a single bonding point for
grounding.
4. All ground wires must be as short and as
thick as possible.
5. Prevent unnecessary turns or loops in all
ground wires.
Ground Rod
Earth Ground
Caution – Do not connect the power harness to the board
until the installation is ready for verification.
Power Harness