Specifications

TECHNICAL SUPPORT 1 800 908 0884
15
The Limit Switches are wired as shown
Lower Limit Switch
Red
Black
Green
White
Upper Cam
Upper Limit Switch
NC
NO
COM
NC
NO
COM
1. Setup the limit switches manually at the desired open and close position.
2. Allow the gate operator to run a full open and close cycle (from limit to limit)
without interruption.
Note: During the first full open and close cycle: The gate operator doesn’t slow
down prior to reaching its limits. During subsequent cycles: The gate operator will
slow down prior to reaching its limits.
3. Verify that the gate opens and closes to the desired position.
To change the open or close limit position(s) the following steps MUST BE taken:
A. Reset the gate operator by performing one of the following steps:
i. Disconnect the power harness or
ii. Disconnect the motor harness or
iii.Actuate both limits at the same time
B. Repeat steps 1,2 and 3.
Limit Switch Connections
Opening/Closing Setup
GATE OPERATOR INSTALLATIONGATE OPERATOR INSTALLATION
Fast
SlowSlow