Specifications
TECHNICAL SUPPORT 1 800 908 0884
14 18
STEP 4
Remove the operator cover.
Lower Cam
Lower Limit Switch
Upper Cam
Upper Limit Switch
Lower Cam
Lower Limit Switch
Upper Cam
Upper Limit Switch
STEP 5
A. Loosen the screws on the limit switch cams.
B. Move the gate manually to the right
position (either fully open or fully closed,
depending on installation configuration).
C. Rotate the lower cam counter-clockwise
until it just actuates the lower limit
switch (until the switch ‘clicks’).
D. Tighten the screw on the lower limit
switch cam.
E. Move the gate manually to the left position.
F. Rotate the upper cam clockwise until it
just actuates the upper limit switch.
G. Tighten the screw on the upper limit
switch cam.
Note:
1. Ensure that the cams are moving freely
between operating the limit switches.
2. Check the vertical position of the cams on
the shaft to ensure they are lined up with
their respective cam levers.
3. The Bottom limit switch is used to stop the
travel of the gate going in the Right direction.
3. The To p limit switch is used to stop the
travel of the gate going in the Left direction.
Note: Leave cover off until after the installation
of the control box and the electrical
installation. Verify that the operator opens
and closes to the desired position under
power. Make any adjustments as necessary.
STEP 6
Replace the operator cover.
Lower Cam
Spacer
Spacer
Upper Cam
Upper Limit Switch
Lower Limit Switch
Limit Switch Bracket
Limit Switch Setup