Specifications

TECHNICAL SUPPORT 1 800 908 0884 Se habla Español
3528
TROUBLESHOOTINGTROUBLESHOOTING
Gate does not run – Check motor indicator comes ON
Check all motor connections to
be fully engaged. Refer to page
15 and 16.
Ensure that the motor
connections are:
a) Properly connected,
Refer to page 15.
Check that all motor cable
connections, junctions and
extensions are properly
connected and color-coded.
Refer to page 15.
Check the 15 Amp fuse in the
control board.
Ensure that the manual reset switch is at the ‘reset’ position.
Refer to page 7 and 28.
Gate does not run – Check motor indicator is OFF
Check all motor connections to
be fully engaged. Refer to page
15.
Check that limit switches are
connected to the common and
the normally close position
refer to page 16.
Check that the stop command
is not active. Refer to page 8
and 25.
Gate does not run – Power failure
Check the 15 Amp battery fuse. Check the battery connections
and cables.
Check the voltage of the
battery.
Gate does not run – Obstruction sensor ON and audio alarm is SOUNDING
Ensure that the gate path is
clear of obstructions.
Note: T
o stop the audio alarm,
use the stop command. Refer
to page 8 and 25.
Adjust the trim pot of the
obstruction sensor. Refer to
page 27.
Gate runs, stops and reverse momentarily – Obstruction sensor ON and audio alarm OFF
Ensure that the gate path is
clear of obstructions.
Check for proper functionality
and lubrication of the gate and
hardware (hinges and the like).
Adjust the trim pot of the
obstruction sensor. Refer to
page 27.
Gate ignores the limit switches
Check that the open limit
switch and close limit switch
are in the corresponding place.
Refer to page 16.
Check that all motor cable
connections, junctions and
extensions are properly connect-
ed and color-coded. Specifically
check the blue and black motor
leads. Refer to page 16.
Check that the UL command
(photo beam and/or edge
sensor) is not active. Refer to
page 6, 7 and 23.
Check that the vehicular loop
detectors are working properly.
Refer to page 20, 21 and 23.
Check that the radio command
is not active. Refer to page 24.
Ensure that you external acces-
sories are working properly.
Check the 4 Amps fuse in the
control board
Ensure that you power cables are
adequate in voltage and properly
connected. Refer to page 14.
Check that the limit switch is
not faulty
Check that wires to the limit
switch are not shorted.