User's Manual

VIKING TECHNICAL SUPPORT 1.800.908.0884
40
TROUBLESHOOTING
LCD Display References
LCD MSG Meaning
Page 41
TS Ref #s
Error Messages
ERR AC
LOW
Indicates that the 24VAC supply to the VFlex Board is too low from the
115/230 power supply.
1, 3. 20
ERR AC
HIGH
Indicates that the 24VAC supply to the VFlex Board is too high from the
115/230 power supply.
1, 3, 20
ERR AC
NO AC
Indicates that there is no 24VAC supply detected to the VFlex Board from
the 115/230 power supply.
1, 2, 4,
20
ERR CHRG
HIGH
Potential problem with the charging voltage from the control board.
1, ?
ERR CHRG
CHECK 4A
a) 4 Amp Fuse is blown, or;
b) There is a problem with the batteries or the control board.
18, ?
ERR BAT
LOW
The battery voltage is low.
1, 2, 3,
4
ERR EPS2
WRONG
The EPS (Electronic Positioning Sensor) has one of the following
conditions: a) The EPS is not properly adjusted b) The EPS has a potential
connection problem c) The EPS has the wrong cable harness
?
ERR EPS2
MISSING
Missing or damaged EPS2 cable harness
14, 17
ERR ___
LIMIT
Indicates that the open “OPN”, close “CLS“ or both “NO“ limits are cleared
and need to be set.
6
ERR FUSE
30 AMP
Motor Power Switch has been tripped.
7, 11, 12
ERR EMI
NO EMI
No EMI board detected.
15
ERR EMI
NO FUSE
8 Amp main fuse is blown on Power Supply Panel Assembly.
2
ERR EMI
NO AC
There is no AC voltage detected from the EMI Board.
20
ERR EMI
Unknown
There is a problem with the communication between the EMI Board and the
VFlex Board.
21
ERR EMI
PROTECT
Lightning strike protection for the EMI Board (behind the Power Supply
Panel Assembly) needs to be replaced.
?
ERR NO
POS STOP
Duringtherstlearncycle,couldnotlocatetheinstalledclosePositive
Stop, within 2 feet of the Close Limit position.
6