SUPER X7DVL-E USER’S MANUAL Revision 1.
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this manual, please see our web site at www.supermicro.com.
Preface Preface About This Manual This manual is written for system integrators, PC technicians and knowledgeable PC users. It provides information for the installation and use of the X7DVL-E motherboard. The X7DVL-E supports dual Intel Xeon dual core processors (w/771 LGA) with a front side bus speed of of 667 MHz/1.066 GHz/1.333 GHz.
X7DVL-E User's Manual Table of Contents Preface About This Manual ...................................................................................................... iii Manual Organization ................................................................................................... iii Conventions Used in the Manual .................................................................................. iii Chapter 1: Introduction 1-1 Overview .........................................................
Table of Contents Reset Button ......................................................................................... 2-13 Power Button .......................................................................................... 2-13 2-5 Connecting Cables ......................................................................................... 2-14 ATX Power Connector .......................................................................... 2-14 Processor Power Connector ..................................
X7DVL-E User's Manual Before Power On....................................................................................... 3-1 No Power................................................................................................... 3-1 No Video .................................................................................................. 3-1 Losing the System’s Setup Configuration ................................................ 3-1 Memory Errors......................................................
Chapter 1: Introduction Chapter 1 Introduction 1-1 Overview Checklist Congratulations on purchasing your computer motherboard from an acknowledged leader in the industry. Supermicro boards are designed with the utmost attention to detail to provide you with the highest standards in quality and performance. Check that the following items have all been included with your motherboard. If anything listed here is damaged or missing, contact your retailer. All are included in the Retail Box.
X7DVL-E User's Manual Contacting Supermicro Headquarters Address: Tel: Fax: Email: Web Site: SuperMicro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. +1 (408) 503-8000 +1 (408) 503-8008 marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) www.supermicro.com Europe Address: Tel: Fax: Email: SuperMicro Computer B.V. Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands +31 (0) 73-6400390 +31 (0) 73-6416525 sales@supermicro.
Chapter 1: Introduction Figure 1-1. X7DVL-E Image (*Note: The drawings and pictures shown in this manual were based on the latest PCB Revision available at the time of publishing of the manual. The motherboard you’ve received may or may not look exactly the same as the graphics shown in the manual.
X7DVL-E User's Manual Figure 1-2.
Chapter 1: Introduction Quick Reference (X7DVL-E) Jumper Description Default Setting JBT1 JI2C1/JI2C2 CMOS Clear See Chapter 2 SMB to PCI Slot#1/Slot#2 Speed Pins 2-3 (Disabled) JPG1 JPL1/ JPL2 VGA Enable GLAN1/GLAN2 Enable Pins 1-2 (Enabled) Pins 1-2 (Enabled) JPWF PWR Supply Failure Detect Off (Disabled) JWD Watch Dog Pins 1-2 (Reset) Connector Description ATX PWR (JPW1) CPU PWR (JPW3) Primary 24-Pin ATX PWR Connector +12V 8-pin PWR Alarm Reset (JAR) Alarm Reset Header Chassis Intr
X7DVL-E User's Manual Motherboard Features CPU • Dual Intel® 64-bit Xeon LGA 771 dual core processors at a front side bus speed of 1333 MHz/1067 MHz/667MHz Memory • Six 240-pin DIMM sockets with support up to 16 GB ECC FBD (Fully Buffered) DDR2 667/533 Memory (*See Section 2-3 in Chapter 2 for DIMM Slot Population.
Chapter 1: Introduction ACPI Features • Slow blinking LED for suspend state indicator • Main switch override mechanism • ACPI Power Management • Power-on mode for power recovery Onboard I/O • Six SATA ports (supporting RAID0, RAID1, RAID10 and RAID5) • One SIMLC IPMI 2.0 socket • Two Giga-bit LAN ports supported by the ESB 2 South Bridge • One EIDE Ultra DMA/100 bus master interface • One floppy port interface • Two COM ports(1 header, 1 port) • One EPP/ECP Parallel Header • Up to six USB 2.
X7DVL-E User's Manual VRM VRM 1067/1333 MT/S PCI-EXP_X8_SLOT PCI-Ex8 PORT #1,2 PORT #0 FBD CHNL1 PCIE X4 PORT #4 PORT #3 ATA 100 #5 #4 #3 #2 #1 #0 ESB2 3Gb/S PCI-X 133 J6 #1 #5 #4 #3 #2 #1 #0 USB 2.0 USB J11 #2 PCI32_SLOT PCI-33MHz LPC KUMERAN RJ45 SIO W83627 HF GB LAN GILGAL FWH RJ45 PARALLEL PORT Figure 1-9.
Chapter 1: Introduction 1-2 Chipset Overview Built upon the functionality and the capability of the 5000V (Blackford-VS) chipset, the X7DVL-E motherboard provides the performance and feature set required for dual processor-based servers with configuration options optimized for communications, presentation, storage, computation or database applications. The 5000V (Blackford-VS) chipset supports a single or dual Dempsey/Woodcrest 64-bit dual core processor(s) with front side bus speeds of up to 1.333 GHz.
X7DVL-E User's Manual 1-3 Special Features Recovery from AC Power Loss BIOS provides a setting for you to determine how the system will respond when AC power is lost and then restored to the system. You can choose for the system to remain powered off (in which case you must hit the power switch to turn it back on) or for it to automatically return to a power- on state. See the Power Lost Control setting in the Advanced BIOS Setup section (Boot Features) to change this setting.
Chapter 1: Introduction CPU Overheat LED and Control This feature is available when the user enables the CPU overheat warning function in the BIOS. This allows the user to define an overheat temperature. When this temperature is exceeded, both the overheat fan and the warning LED are triggered. System Resource Alert This feature is available when used with Supero Doctor III in the Windows OS environment or used with Supero Doctor II in Linux. SDIII is used to notify the user of certain system events.
X7DVL-E User's Manual the system malfunctions and you want to turn off the power, just depress and hold the power button for 4 seconds. This option can be set in the Power section of the BIOS Setup routine. External Modem Ring-On Wake-up events can be triggered by a device such as the external modem ringing when the system is in the Standby or Off state. Note that external modem ring-on can only be used with an ATX 2.01 (or above) compliant power supply.
Chapter 1: Introduction or 1 Mb/s.It also provides two high-speed, 16550 compatible serial communication ports (UARTs), one of which supports serial infrared communication. Each UART includes a 16-byte send/receive FIFO, a programmable baud rate generator, complete modem control capability and a processor interrupt system. Both UARTs provide legacy speed with baud rate of up to 115.2 Kbps as well as an advanced speed with baud rates of 250 K, 500 K, or 1 Mb/s, which support higher speed modems.
X7DVL-E User's Manual Notes 1-14
Chapter 2: Installation Chapter 2 Installation 2-1 Static-Sensitive Devices Electric-Static-Discharge (ESD) can damage electronic components. To prevent damage to your system board, it is important to handle it very carefully. The following measures are generally sufficient to protect your equipment from ESD. Precautions • Use a grounded wrist strap designed to prevent static discharge. • Touch a grounded metal object before removing the board from the antistatic bag.
X7DVL-E User's Manual 2-2 Processor and Heatsink Fan Installation ! When handling the processor package, avoid placing direct pressure on the label area of the fan. *Notes: 1. Always connect the power cord last and always remove it before adding, removing or changing any hardware components. Make sure that you install the processor into the CPU socket before you install the CPU heatsink. 2. Intel's boxed Xeon CPU package contains the CPU fan and heatsink assembly.
Chapter 2: Installation North Center Edge 3. Use your thumb and your index finger to hold the CPU at the North Center Edge and the South Center Edge of the CPU. 4. Align CPU Pin1 (the CPU corner marked with a triangle) against the socket corner that is marked with a South Center Edge triangle cutout. gold dot 5. Align the the CPU key that is the Socket Key semi-circle cutout below a gold dot (Socket Notch) against the socket key, the notch on the same side of the triangle cutout on the socket. 6.
X7DVL-E User's Manual Installation of the Heatsink CEK Passive Heatsink CEK Heatsink Installation 1. Do not apply any thermal grease to the heatsink or the CPU die; the required amount has already been applied. 2. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the retention mechanism. 3. Screw in two diagonal screws (ie the #1 and the #2 screws) until just snug (-do not fully tighten the screws to avoid possible damage to the CPU.
Chapter 2: Installation 1. Unscrew and remove the heatsink screws from the motherboard in the sequence as show in the picture on the right. 2. Hold the heatsink as show in the picture on the right and gently wriggle the heatsink to loosen it from the CPU. (Do not use excessive force when wriggling the heatsink!!) 3. Once the heatsink is loosened, remove the heatsink from the CPU socket. 4. Clean the surface of the CPU and the heatsink to get rid of the old thermal grease.
X7DVL-E User's Manual 2-3 Installing DIMMs Note: Check the Supermicro web site for recommended memory modules. CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Also note that the memory is interleaved to improve performance (see step 1). DIMM Installation (See Figure 2-2) 1. Insert the desired number of DIMMs into the memory slots, starting with DIMM #1A.
Chapter 2: Installation Figure 2-2. Installing and Removing DIMMs DDR ® D®DI SUPER ®X7DVL-E To Install: Insert module vertically and press down until it snaps into place. Pay attention to the alignment notch at the bottom. To Remove: Use your thumbs to gently push the release tabs near both ends of the module. This should release it from the slot.
X7DVL-E User's Manual 2-4 Control Panel Connectors/IO Ports The I/O ports are color coded in conformance with the PC 99 specification. See Figure 2-3 below for the colors and locations of the various I/O ports. A. Back Panel Connectors/IO Ports 2 4 1 3 ® SUPER X7DVL-E 5 6 7 8 Figure 2-3. Back Panel I/O Port Locations and Definitions Back Panel Connectors 1. Keyboard (Purple) 2. PS/2 Mouse (Green) 3. Back Panel USB Port 0 4. Back Panel USB Port 1 5. COM Port 1 (Turquoise) 6. VGA Port (Blue) 7.
Chapter 2: Installation B. Front Control Panel JF1 contains header pins for various buttons and indicators that are normally located on a control panel at the front of the chassis. These connectors are designed specifically for use with Supermicro server chassis. See Figure 2-4 for the descriptions of the various control panel buttons and LED indicators. Refer to the following section for descriptions and pin definitions. Figure 2-4.
X7DVL-E User's Manual C. Front Control Panel Pin Definitions NMI Button NMI Button Pin Definitions (JF1) The non-maskable interrupt button Pin# Definition header is located on pins 19 and 20 19 Control 20 Ground of JF1. Refer to the table on the right for pin definitions. Power LED The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table on the right for pin definitions.
Chapter 2: Installation HDD LED HDD LED Pin Definitions (JF1) The HDD LED connection is located on pins 13 and 14 of JF1. Attach the hard drive LED cable here to display disk activity (for any hard drives on Pin# Definition 13 +5V 14 HD Active the system, including SAS, Serial ATA and IDE). See the table on the right for pin definitions.
X7DVL-E User's Manual Overheat/Fan Fail LED (OH) OH/Fan Fail LED Pin Definitions (JF1) Connect an LED to the OH/Fan Fail connection on pins 7 and 8 of JF1 to Pin# Definition 7 Vcc provide advanced warning of chassis overheating or fan failure. Refer to 8 Ground the table on the right for pin defini- OH/Fan Fail Indicator Status tions.
Chapter 2: Installation Reset Button The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to the Reset Button Pin Definitions (JF1) hardware reset switch on the computer case. Refer to the table on the right for Pin# Definition 3 Reset pin definitions. 4 Ground Power Button The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system.
X7DVL-E User's Manual 2-5 ATX Power 20-pin Connector Pin Definitions Connecting Cables ATX Power Connector There are a 24-pin main power supply connector(JPW1) and an 8-pin CPU PWR connector (JPW3) on the motherboard. These power connectors meet the SSI EPS 12V specification. See the table on the right for pin definitions. For the 8-pin PWR (JPW3), please refer to the item listed below. Pin# Definition 13 +3.3V 1 +3.3V 14 -12V 2 +3.
Chapter 2: Installation Back Panel USB (USB0/1) Universal Serial Bus (USB) Front Panel USB (USB2/3) There are six USB 2.0 (Universal Pin# Definitions Pin# Definition Serial Bus) ports/headers on the 1 +5V 1 Vcc motherboard. Two of them are Back Panel USB ports (USB#0/1:J20), 2 PO- 2 PO- 3 PO+ 3 PO+ and the other three are Front Panel 4 Ground 4 Ground USB headers (USB#2/3:JUSB1, 5 N/A 5 Key USB#4: JUSB2).
X7DVL-E User's Manual Fan Headers Fan Header Pin Definitions (Fan1-6) The X7DVL-E has four chassis/system fan headers (Fan3 to Fan6) and two CPU Fans (Fans 1/2). (*Note: all these fans are 4-pin fans. However, Pins 1-3 of the fan headers are backward compatible with the traditional 3-pin fans.) See the table on the right for pin defini- Pin# Definition 1 Ground 2 +12V 3 Tachometer 4 PWR Modulation tions.
Chapter 2: Installation ATX PS/2 Keyboard and PS/2 Mouse Ports PS/2 Keyboard and Mouse Port Pin Definitions The ATX PS/2 keyboard and the PS/2 Pin# Definition mouse are located at JKM1. See the 1 Data table on the right for pin definitions. (The mouse port is above the key- 2 NC 3 Ground board port. See the table on the right 4 VCC for pin definitions.
X7DVL-E User's Manual Wake-On-Ring Wake-On-Ring Pin Definitions (JWOR) The Wake-On-Ring header is designated JWOR. This function allows your computer to receive and be "waken up" by an incoming call to Pin# Definition 1 Ground 2 Wake-up the modem when the system is in the suspend state. See the table on the right for pin definitions. You must have a Wake-On-Ring card and cable to use this feature.
Chapter 2: Installation GLAN 1/2 (Giga-bit Ethernet Ports) GLAN1 Two G-bit Ethernet ports are designated JLAN1 and JLAN2 on the I/O GLAN2 backplane. This port accepts RJ45 type cables. Power LED/Speaker Speaker Connector On the JD1 header, pins 1-3 are for a power LED and pins 4-7 are for the speaker.. See the table on the right for speaker pin definitions. Note: The speaker connector pins are for use with an external speaker.
X7DVL-E User's Manual Alarm Reset Alarm Reset If three power supplies are installed Pin Setting and Alarm Reset (JAR) is enabled, the system will notify you when any of the three power modules fail. Connect Definition Pin 1 Ground Pin 2 +5V JAR to a micro-switch to enable you to turn off the alarm that is activated when a power module fails. See the table on the right for pin definitions. SMB SMB Header Pin Definitions A System Management Bus header is located at J18.
Chapter 2: Installation Power SMB (I2 C) Connector PWR SMB Pin Definitions Power SMB (I2 C) Connector (JPI2 C) monitors the status of the power supply, Fan and system temperature. See the table on the right for pin definitions. Pin# Definition 1 Clock 2 Data 3 PWR Fail 4 Ground 5 +3.3V VGA Connector A VGA connector (J15) is located next to the COM1 port on the IO backplane. Refer to the board layout below for the location.
X7DVL-E User's Manual 2-6 Jumper Settings Explanation of Jumpers Connector Pins 3 2 1 3 2 1 To modify the operation of the motherboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function Jumper Cap of the connector. Pin 1 is identified with a square solder pad on the printed circuit Setting board. See the motherboard layout Pin 1-2 short pages for jumper locations.
Chapter 2: Installation CMOS Clear JBT1 is used to clear CMOS. Instead of pins, this "jumper" consists of contact pads to prevent the accidental clearing of CMOS. To clear CMOS, use a metal object such as a small screwdriver to touch both pads at the same time to short the connection. Always remove the AC power cord from the system before clearing CMOS. Note: For an ATX power supply, you must completely shut down the system, remove the AC power cord and then short JBT1 to clear CMOS.
X7DVL-E User's Manual VGA Enable/Disable VGA Enable/Disable Jumper Settings JPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2 to enable VGA. See the table on the right for jumper settings. Both Jumpers Definition Pins 1-2 Enabled (*Default) Pins 2-3 Disabled I2C Bus to PCI Slots I2C to PCI-Slots Jumper Settings Jumpers JI2C1/JI2C2 allow you to connect the System Management Bus (I2C) to PCI slots.
Chapter 2: Installation PWR Supply Failure/PWR Fault Detect (JPWF) PWR Supply PWR Fault Jumper Settings Jumper Setting The system can notify you in the event of a power supply failure. This feature is available when three power supply units are installed in the chassis with one act- Definition Closed Enabled Open Disabled (*Default) ing as a backup. If you only have one or two power supply units installed, you should disable this (the default setting) with JPWF to prevent false alarms.
X7DVL-E User's Manual 2-7 Onboard Indicators Activity Link LED LED GLAN LEDs GLAN Activity Indicator There are two GLAN ports on the motherboard. Each Gigabit Ethernet LAN port Color Status Definition has two LEDs. The green LED indicates activity, while the power LED may be Amber Flashing Active GLAN Link Indicator green, orange or off to indicate the speed of the connection. See the tables at right LED Color Definition for more information.
Chapter 2: Installation POST Code LED Indicators (LE4, LE5) POST Code LED Indicators There are two POST Code LED Indicators LE4 (LE4, LE5) located on the motherboard.
X7DVL-E User's Manual 2-8 Parallel Port, Floppy Drive, SIMLP IPMI and Hard Disk Drive Connections Note the following when connecting the floppy and hard disk drive cables: • The floppy disk drive cable has seven twisted wires. • A red mark on a wire typically designates the location of pin 1. Parallel (Printer) Port Connector Parallel (Printer) Port Connector Pin Definitions 8-Pin PWR JPWF KB/ Mouse 24-Pin ATX PWR PWR I2C Fan1 The parallel (printer) port is located between PCI Slot#2 and PCI Slot#3.
Chapter 2: Installation Floppy Connector Floppy Drive Connector Pin Definitions (Floppy) The floppy connector is located on Pin# Definition J22. 1 Ground 2 FDHDIN 3 Ground 4 Reserved 5 Key 6 FDEDIN 7 Ground 8 Index 9 Ground 10 Motor Enable 11 Ground 12 Drive Select B 13 Ground 14 Drive Select B 15 Ground 16 Motor Enable See the table below for pin definitions. SIMLC IPMI Slot There is a SIMLC IPMI Slot on the motherboard.
X7DVL-E User's Manual IDE Connector IDE Drive Connectors Pin Definitions There is one IDE Connector (JIDE1) on Pin# Definition the motherboard.
Chapter 3: Troubleshooting Chapter 3 Troubleshooting 3-1 Troubleshooting Procedures Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the ‘Technical Support Procedures’ and/or ‘Returning Merchandise for Service’ section(s) in this chapter. Note: Always disconnect the power cord before adding, changing or installing any hardware components. Before Power On 1.
X7DVL-E User's Manual supply may cause the system to lose the CMOS setup information. Refer to Section 1-6 for details on recommended power supplies. 2. The battery on your motherboard may be old. Check to verify that it still supplies ~3VDC. If it does not, replace it with a new one. 3. If the above steps do not fix the Setup Configuration problem, contact your vendor for repairs. NOTE If you are a system integrator, VAR or OEM, a POST diagnostics card is recommended. For I/O port 80h codes, refer to App.
Chapter 3: Troubleshooting 3. If you still cannot resolve the problem, include the following information when contacting Super Micro for technical support: • Motherboard model and PCB revision number • BIOS release date/version (this can be seen on the initial display when your system first boots up) •System configuration An example of a Technical Support form is on our web site at http://www.supermicro.com/techsupport/contact_support.htm. 4.
X7DVL-E User's Manual 3-4 Returning Merchandise for Service A receipt or copy of your invoice marked with the date of purchase is required before any warranty service will be rendered. You can obtain service by calling your vendor for a Returned Merchandise Authorization (RMA) number. When returning to the manufacturer, the RMA number should be prominently displayed on the outside of the shipping carton, and mailed prepaid or hand-carried.
Chapter 4: BIOS Chapter 4 BIOS 4-1 Introduction This chapter describes the Phoenix BIOS™ Setup utility for the X7DVL-E. The Phoenix ROM BIOS is stored in a flash chip and can be easily upgraded using a floppy disk-based program. Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual. Please refer to the Manual Download area of the Supermicro web site
X7DVL-E User's Manual 4-2 Running Setup *Default settings are in bold text unless otherwise noted. The BIOS setup options described in this section are selected by choosing the appropriate text from the main BIOS Setup screen. All displayed text is described in this section, although the screen display is often all you need to understand how to set the options (see next page). When you first power on the computer, the Phoenix BIOS™ is immediately activated.
Chapter 4: BIOS Main BIOS Setup Menu Main Setup Features System Time To set the system date and time, key in the correct information in the appropriate fields. Then press the key to save the data. System Date Using the arrow keys, highlight the month, day and year fields, and enter the correct data. Press the key to save the data. BIOS Date This field displays the date when this version of BIOS was built.
X7DVL-E User's Manual IDE Channel 0 Master/Slave, IDE Channel 1 Master/Slave, SATA Port2 and SATA Port3 These settings allow the user to set the parameters of IDE Channel 0 Master/ Slave, IDE Channel 1 Master/Slave, IDE Channel 2 Master, IDE Channel 3 Master slots. Hit to activate the following sub-menu screen for detailed options of these items. Set the correct configurations accordingly. The items included in the sub-menu are: Type Selects the type of IDE hard drive.
Chapter 4: BIOS CHS Format The following items will be displayed by the BIOS: TYPE: This item displays the type of IDE or SATA Device. Cylinders: This item indicates the status of Cylinders. Headers: This item indicates the number of headers. Sectors: This item displays the number of sectors. Maximum Capacity: This item displays the maximum storage capacity of the system.
X7DVL-E User's Manual Parallel ATA This setting allows the user to enable or disable the function of Parallel ATA. The options are Disabled, Channel 0, Channel 1, and Both. Serial ATA This setting allows the user to enable or disable the function of Serial ATA. The options are Disabled and Enabled. Native Mode Operation Select the native mode for ATA. The options are: Parallel ATA, Serial ATA, Both, and Auto.
Chapter 4: BIOS System Memory This display informs you how much system memory is recognized as being present in the system. Extended Memory This display informs you how much extended memory is recognized as being present in the system. 4-4 Advanced Setup Choose Advanced from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. The items with a triangle beside them have sub menus that can be accessed by highlighting the item and pressing .
X7DVL-E User's Manual Boot Features Access the submenu to make changes to the following settings. Quick Boot Mode If enabled, this feature will speed up the POST (Power On Self Test) routine by skipping certain tests after the computer is turned on. The settings are Enabled and Disabled. If Disabled, the POST routine will run at normal speed. Quiet Boot This setting allows you to Enable or Disable the graphic logo screen during boot-up.
Chapter 4: BIOS Memory Cache Cache System BIOS Area This setting allows you to designate a reserve area in the system memory to be used as a System BIOS buffer to allow the BIOS write (cache) its data into this reserved memory area. Select "Write Protect" to enable this function, and this area will be reserved for BIOS ROM access only. Select "Uncached" to disable this function and make this area available for other devices.
X7DVL-E User's Manual Select "Uncached" to disable this function. Select "Write Through" to allow data to be cached into the buffer and written into the system memory at the same time. Select "Write Protect" to prevent data from being written into the base memory area of Block 0-512K. Select "Write Back" to allow CPU to write data back directly from the buffer without writing data to the System Memory for fast CPU data processing and operation.
Chapter 4: BIOS Slot1 PCI 33MHz, Slot2 PCI 33MHz, Slot3 PCI-Exp x8, Slot4 PCIExp x4, Slot5 PCI-X 133MHz, Slot6 PCI-X 133MHz Access the submenu for each of the settings above to make changes to the following: Option ROM Scan When enabled, this setting will initialize the device expansion ROM. The options are Enabled and Disabled. Enable Master This setting allows you to enable the selected device as the PCI bus master. The options are Enabled and Disabled.
X7DVL-E User's Manual Memory Branch Mode This option determines how the memory branch operates. System address space can either be interleaved between two channels or Sequential from one channel to another. Single Channel 0 allows a single DIMM population during system manufacturing. The options are Interleave, Sequential and Single Channel 0. Branch 0 Rank Sparing Select enable to enable the sparing feature for Branch 0 Rank. The options are Enabled and Disabled.
Chapter 4: BIOS Advanced Processor Options Access the submenu to make changes to the following settings. CPU Speed This is a display that indicates the speed of the installed processor. Frequency Ratio (*Available when supported by the CPU.) The feature allows the user to set the internal frequency multiplier for the CPU. The options are: Default, x12, x13, x14, x15, x16, x17 and x18. Hyperthreading (*Available when supported by the CPU.
X7DVL-E User's Manual Adjacent Cache Line Prefetch (*Available when supported by the CPU.) The CPU fetches the cache line for 64 bytes if this option is set to Disabled. The CPU fetches both cache lines for 128 bytes as comprised if Enabled. The options are Disabled and Enabled. Hardware Prefetcher (*Available when supported by the CPU.
Chapter 4: BIOS Interrupt This setting allows you to select the IRQ (interrupt request) for serial port A. The options are IRQ3 and IRQ4. Serial Port B This setting allows you to assign control of serial port B. The options are Enabled (user defined), Disabled, Auto (BIOS controlled) and OS Controlled. Mode This setting allows you to set the type of device that will be connected to serial port B. The options are Normal and IR (for an infrared device).
X7DVL-E User's Manual DMI Event Logging Access the submenu to make changes to the following settings. Event Log Validity This is a display to inform you of the event log validity. It is not a setting. Event Log Capacity This is a display to inform you of the event log capacity. It is not a setting. View DMI Event Log Highlight this item and press to view the contents of the event log. Event Logging This setting allows you to Enable or Disable event logging.
Chapter 4: BIOS Console Redirection Access the submenu to make changes to the following settings. COM Port Address This item allows you to specify to redirect the console to Onboard COM A or Onboard COM B. This setting can also be Disabled. BAUD Rate This item allows you to select the BAUD rate for console redirection. The options are 300, 1200, 2400, 9600, 19.2K, 38.4K, 57.6K, and 115.2K.
X7DVL-E User's Manual Hardware Monitor Logic *Note: The Phoenix BIOS will automatically detect the type of CPU(s) and hardware monitoring chip used on the motherboard and will display the Hardware Monitoring Screen accordingly. Your Hardware Monitoring Screen may look like the one shown on this page, on P. 4-19, or on P. 4-20, depending on the type of CPU(s) and HW Monitoring chip you are using.
Chapter 4: BIOS Hardware Monitor Logic CPU Temperature Threshold (*See the Note on Page 4-18.) This option allows the user to set a CPU temperature threshold that will activate the alarm system when the CPU temperature reaches this pre-set temperature threshold. The options are 70oC, 75oC, 80oC and 85oC.
X7DVL-E User's Manual Hardware Monitor Logic (*See the Note on Page 4-18.) CPU Temperature Threshold This option allows the user to set a CPU temperature threshold that will activate the alarm system when the CPU temperature reaches this pre-set temperature threshold. The hardcode default setting is 75oC.
Chapter 4: BIOS IPMI (The option is available only when an IPMI card is installed in the system.) IPMI Specification Version: This item displays the current IPMI Version. Firmware Version: This item displays the current Firmware Version. System Event Logging Select Enabled to enable IPMI Event Logging. When this function is set to Disabled, the system will continue to log events received via system interface. The options are Enabled and Disabled.
X7DVL-E User's Manual OS Boot Watch Dog Set to Enabled to enable OS Boot Watch Dog. The options are Enabled and Disabled. Timer for Loading OS (Minutes) This feature allows the user to set the time value (in minutes) for the previous item: OS Boot Watch Dog by keying-in a desired number in the blank. The default setting is 10 (minutes.) (Please ignore this option when OS Boot Watch Dog is set to "Disabled".
Chapter 4: BIOS Realtime Sensor Data This feature display information from motherboard sensors, such as temperatures, fan speeds and voltages of various components.
X7DVL-E User's Manual 4-5 Security Choose Security from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. Security setting options are displayed by highlighting the setting using the arrow keys and pressing . All Security BIOS settings are described in this section. Supervisor Password Is: This displays whether a supervisor password has been entered for the system.
Chapter 4: BIOS Password on Boot This setting allows you to require a password to be entered when the system boots up. The options are Enabled (password required) and Disabled (password not required). 4-6 Boot Choose Boot from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. See details on how to change the order and specs of boot devices in the Item Specific Help window. All Boot BIOS settings are described in this section.
X7DVL-E User's Manual 4-7 Exit Choose Exit from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. All Exit BIOS settings are described in this section. Exit Saving Changes Highlight this item and hit to save any changes you made and to exit the BIOS Setup utility. Exit Discarding Changes Highlight this item and hit to exit the BIOS Setup utility without saving any changes you may have made.
Appendix A: BIOS POST Messages Appendix A BIOS POST Messages During the Power-On Self-Test (POST), the BIOS will check for problems. If a problem is found, the BIOS will activate an alarm or display a message. The following is a list of such BIOS messages. Failure Fixed Disk Fixed disk is not working or not configured properly. Check to see if fixed disk is attached properly. Run Setup. Find out if the fixed-disk type is correctly identified. Stuck key Stuck key on keyboard.
X7DVL-E User's Manual System CMOS checksum bad - Default configuration used System CMOS has been corrupted or modified incorrectly, perhaps by an application program that changes data stored in CMOS. The BIOS installed Default Setup Values. If you do not want these values, enter Setup and enter your own values. If the error persists, check the system battery or contact your dealer. System timer error The timer test failed. Requires repair of system board.
Appendix A: BIOS POST Messages System cache error - Cache disabled RAM cache failed and BIOS disabled the cache. On older boards, check the cache jumpers. You may have to replace the cache. See your dealer. A disabled cache slows system performance considerably. CPU ID: CPU socket number for Multi-Processor error. EISA CMOS not writeable ServerBIOS2 test error: Cannot write to EISA CMOS. DMA Test Failed ServerBIOS2 test error: Cannot write to extended DMA (Direct Memory Access) registers.
X7DVL-E User's Manual Fixed Disk n Fixed disk n (0-3) identified. Invalid System Configuration Data Problem with NVRAM (CMOS) data. I/O device IRQ conflict I/O device IRQ conflict error. PS/2 Mouse Boot Summary Screen: PS/2 Mouse installed. nnnn kB Extended RAM Passed Where nnnn is the amount of RAM in kilobytes successfully tested. nnnn Cache SRAM Passed Where nnnn is the amount of system cache in kilobytes successfully tested.
Appendix A: BIOS POST Messages Parity Check 2 nnnn Parity error found in the I/O bus. BIOS attempts to locate the address and display it on the screen. If it cannot locate the address, it displays ????. Press to resume, to Setup, for previous Displayed after any recoverable error message. Press to start the boot process or to enter Setup and change the settings. Press to display the previous screen (usually an initialization error of an Option ROM, i.e., an add-on card).
X7DVL-E User's Manual Notes A-6
Appendix B: BIOS POST Codes Appendix B BIOS POST Codes This section lists the POST (Power On Self Test) codes for the PhoenixBIOS. POST codes are divided into two categories: recoverable and terminal. Recoverable POST Errors When a recoverable type of error occurs during POST, the BIOS will display an POST code that describes the problem.
X7DVL-E User's Manual POST Code Description 18h 1Ah 1Ch 20h 22h 24h 28h 29h 2Ah 2Ch 2Eh 2Fh 32h 33h 36h 38h 3Ah 3Ch 3Dh 41h 42h 45h 46h 48h 49h 4Ah 4Bh 4Ch 4Eh 4Fh 50h 51h 52h 54h 55h 58h 59h 5Ah 5Bh 8254 timer initialization 8237 DMA controller initialization Reset Programmable Interrupt Controller 1-3-1-1 Test DRAM refresh 1-3-1-3 Test 8742 Keyboard Controller Set ES segment register to 4 GB Auto size DRAM Initialize POST Memory Manager Clear 512 kB base RAM 1-3-4-1 RAM failure on address line xxxx* 1-3
Appendix B: BIOS POST Codes POST Code Description 5Ch 60h 62h 64h 66h 67h 68h 69h 6Ah 6Bh 6Ch 70h 72h 76h 7Ch 7Dh 7Eh 80h 81h 82h 83h 84h 85h 86h 87h 88h 89h 8Ah 8Bh 8Ch 8Fh 90h 91h 92h 93h 95h 96h 97h 98h Test RAM between 512 and 640 kB Test extended memory Test extended memory address lines Jump to UserPatch1 Configure advanced cache registers Initialize Multi Processor APIC Enable external and CPU caches Setup System Management Mode (SMM) area Display external L2 cache size Load custom defaults (optiona
X7DVL-E User's Manual POST Code Description 99h 9Ch 9Dh 9Eh 9Fh A0h A2h A4h A8h AAh ACh AEh B0h B1h B2h B4h B5h B6h B7h B9h BAh BCh BDh BEh BFh C0h C1h C2h C3h C4h C6h C7h C8h C9h CDh Check for SMART Drive (optional) Set up Power Management Initialize security engine (optional) Enable hardware interrupts Determine number of ATA and SCSI drives Set time of day Check key lock Initialize typematic rate Erase prompt Scan for key stroke Enter SETUP Clear Boot flag Check for errors Inform RomPilot ab
Appendix B: BIOS POST Codes POST Code Description D2h D4h D8h D9h DEh Unknown interrupt Check Intel Branding string Alert Standard Format initialization Late init for IPMI Log error if micro-code not updated properly The following are for boot block in Flash ROM POST Code E0h E1h E2h E3h E4h E5h E6h E7h E8h E9h EAh EBh ECh EDh EEh EFh F0h F1h F2h F3h F4h F5h F6h F7h Description Initialize the chipset Initialize the bridge Initialize the CPU Initialize system timer Initialize system I/O Check force recov
X7DVL-E User's Manual Notes B-6
Appendix C: The Intel HostRAID Sepup Guidelines Appendix C The Intel HostRAID Setup Guidelines After all the hardware has been installed, you must first configure Intel's ESB2 SATA RAID* before you install the Windows Operating System and other software drivers. Important Notes to the User: *Note 1: If you do not wish to configure onboard SATA RAID functions, please go directly to Section C-3 for Operating System & Other Software Installation.
X7DVL-E User's Manual The Intel HostRAID Configurations The following types of Intel's HostRAID configurations are supported: RAID 0 (Data Striping): this writes data in parallel, interleaved ("striped") sections of two hard drives. Data transfer rate is doubled over using a single disk. RAID1 (Data Mirroring): an identical data image from one drive is copied to another drive. The second drive must be the same size or larger than the first drive.
Appendix C: The Intel HostRAID Sepup Guidelines Using the Intel ESB2 SATA RAID Utility Program 1. Creating, Deleting and Resetting RAID Volumes: a. After the system exits from the BIOS Setup Utility, the system will automatically reboot. The following screen appears after Power-On Self Test. b.
X7DVL-E User's Manual Creating a RAID 0 Volume: a. Select "Create RAID Volume" from the main menu and press the key. The following screen will appear: b. Specify a name for the RAID 0 set and press the key or the key to go to the next field. (You can use the key to select the previous menu.) c. When RAID Level item is highlighted, press the , keys to select RAID 0 (Stripe) and hit . d.
Appendix C: The Intel HostRAID Sepup Guidelines Creating a RAID 1 Volume: a. Select "Create RAID Volume" from the main menu and press the key. The following screen will appear: b. Specify a name for the RAID 1 set and press the key or the key to go to the next field. (You can use the key to select the previous menu.) c. When RAID Level item is highlighted, press the , keys to select RAID 1 (Mirror) and hit . d.
X7DVL-E User's Manual Creating a RAID 10 (RAID 1+ RAID 0): a. Select "Create RAID Volume" from the main menu and press the key. The following screen will appear: b. Specify a name for the RAID 10 set and press . c. When RAID Level item is highlighted, use the , keys to select RAID 10 (RAID1 + RAID0) and hit . d.
Appendix C: The Intel HostRAID Sepup Guidelines Creating a RAID 5 Set (Parity): a. Select "Create RAID Volume" from the main menu and press the key. The following screen will appear: b. Specify a name for the RAID 5 set and press . c. When the Raid Level is highlighted, use the , keys to select RAID 5 (Parity) and hit . d. When the Disk item is highlighted, press to select the HDD to configure as RAID.
X7DVL-E User's Manual Deleting RAID Volume: (Warning: Be sure to back up your data before deleting a RAID set. You will lose all data on the disk drives when deleting a RAID set.) a. From the main menu, select item2-Delete RAID Volume, and press . b. Use the , keys to select the RAID set you want to delete and press . A Warning message displays. c.
Appendix C: The Intel HostRAID Sepup Guidelines Resetting to Non-RAID and Resetting a RAID HDD (Warning: Be cautious when you reset a RAID volume HDD to nonRAID or Resetting a RAID HDD. Resetting a RAID volume HDD or Resetting a RAID HDD will reformat the HDD and delete the internal RAID structure on the drive.) a. From the main menu, select item3-Reset Disks to Non- RAID, and press . The following screen will appear: b.
X7DVL-E User's Manual C-2 Installing the Windows XP/2000/2003 for systems with RAID Functions New Operating System-Windows XP/2000/2003 Installation a. Insert Microsoft Windows XP/2000/2003 Setup CD in the CD Driver, and the system will start booting up from CD. b. Press the key when the message-" Press F6 if you need to install a third party SCSI or RAID driver" displays. c. When the Windows XP/2000/2003 Setup screen appears, press "S" to specify additional device(s). d.
Appendix D: Installing Other Software Programs and Drivers Appendix D Installing Other Software Programs and Drivers A. Installing Drivers other than the Adaptec Embedded Serial ATA RAID Controller Driver After you've installed Windows Operating System, a screen as shown below will appear. You are ready to install software programs and drivers that have not yet been installed. To install these software programs and drivers, click the icons to the right of these items.
X7DVL-E User's Manual B. Configuring Supero Doctor III The Supero Doctor III program is a Web-based management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The Supero Doctor III program included on the CDROM that came with your motherboard allows you to monitor the environment and operations of your system.
Appendix D: Installing Other Software Programs and Drivers Supero Doctor III Interface Display Screen-II (Remote Control) (*Note: SD III Software can be downloaded from our Web site at: ftp://ftp. supermicro.com/utility/Supero_Doctor_III/. You can also download SDIII User's Guide at: http://www.supermicro.com/PRODUCT/Manuals/SDIII/UserGuide.pdf. For Linux, we will still recommend that you use Supero Doctor II.
X7DVL-E User's Manual Notes D-4