User`s guide

12
4-1-1-3-3.COAX [UP THE COAX] Control
MODE: COAX PROTOCOL: PELCO-C
PTZ CONTROL
▲▼: TILT ◀▶: PAN SET: PT <-> ZF MODE: PTZ<->OSD
• It displays the current setting mode at the top of the screen.
• Press SET KEY shortly in MULTI WAY KEY selection to select PAN/TILT mode or
ZOOM/FOCUS mode.
- RED : P.T.Z MODE - BLUE : OSD MODE
In case of BOX/DOME Camera, Hold ENTER KEY to select OSD Menu.
• Press Mode KEY to select CAMERA OSD control mode.
• Press MENU KEY to control CAMERA OSD and ESC KEY to exit OSD MENU.
• Press EXIT KEY to go to the previous mode. (In CAMERA OSD mode, switch to
PAN/TILT mode first in order to exit.)
• Press ◀/▶/▲/▼ buttons following the OSD guidance on the screen.
※ Possible to control in the remote side of max. 800M by COAX communication.
(Standard of RG-6)
• List of controllable models
NO
COMPANY
Monitor OSD
CONTROLLABLE MODEL
01
Samsung Techwin
PELCO-C
All models to support
COAX communication (WINNER 5)
02
PELCO
PELCO-C
All models to support
COAX communication
03
DONGYANG
UNITECH
PELCO-C
All models to support
COAX communication (PIXIM)
※ PELCO-C PROTOCOL in SC-LFC56LC is compatible with all the product models
above. Also, SC-LFC56LC can control COAX in a remote side through the
automatic NTSC/PAL recognition without any set-up.
※ SC-LFC56LC does not support Coax Remote Control in Samsung A One Module.