User manual

Hybrid Portable Test Monitor
13
4-1-1-4-1.RS-485(TX)
• Displaysthecurrentsettingmodeatthetopofthescreen.
• PressSETKEYinMULTIWAYKEYselectiontoselectPAN/TILTorZOOM/FOCUSmode.
-RED:P.T.ZMODE-BLUE:OSDMODE
• PresstheModeKEYtoselectCAMERAOSDcontrolmode.
• PresstheMENUKEYtocontrolCAMERAOSDandpresstheESCKEYtoexitOSDMENU.
• IncaseofBOX/DOMECamera,holdtheENTERKEYtoselecttheOSDMenu.
• PressEXITKEYtogotothepreviousmode
• (inCAMERAOSDmode,switchtoPAN/TILTmoderst,inordertoexit).
• Press///buttonsfollowingtheOSDguidanceonthescreen.
※Caution
• TheHybridTestmonitorhastwodifferentPELCO-DProtocols,whicharePELCO-DPROTOCOL,
PELCO(CNB).
• ForPELCO-DPROTOCOL,itispossibletoenterthecameraOSDmenubyusingMENUkey.
(SETPRESETCOMMAND)
• ForPELCO(CNB)PROTOCOL,itispossibletoenterthecameraOSDmenubyusingMENUkey
(GotoPRESET)orESCkey(RunPRESET)
• Dependingonthecameramanufacturer,thecommandtoenterthecameraOSDMenuisdifferent.
4-1-1-4-2. RX
• Displaysthecurrentsettingmodeatthetopofthescreen.
• DisplaystheconnectionstatusoftheRS-485lineindicatedbyaHEXvalue.
• ThereceiveddataviatheRS-485portisdisplayedasamaximumin8linesinbytes(16byte).
• Whenthedataismorethan128byte,it’sclearedoutautomatically.Youcanalsoclearitout
temporarily,usingtheESCbutton.
• Togotothepreviousmenu,presstheEXITbutton.