Release Notes Kaleido-Alto/Quad/Quad-Dual Version 3.31
Updated: 3 October 2008 Part Number: M785-0203-115 3
(B15454) Alarms, channels, actions or audio scales exported with layouts from KEdit to a Kaleido-
Alto/Quad may not synchronize properly.
(B13613 and B15526) Loss of a dynamic UMD from TSL may occur when using channel assignments or
changing view to full screen.
Version 3.20
New Features
Support for the new Kaleido-Dual Quad series, which includes:
o Kaleido-Quad-Dual-HD (HD/SD-SDI and Composite Dual Quad Split Processor w/redundant PSU)
o Kaleido-Quad-S-HD-R (HD/SD-SDI and Composite Quad Split Processor w/redundant PSU)
Shortcut to return to default resolution (1280 x 1024 @ 60 Hz):
Press Ctrl+Alt+R on a USB keyboard connected to the unit.
Fixes
(B14458) Changing output resolution sometimes doesn’t work (system returns to the default resolution of
1280 x 1024 @ 60 Hz).
(B14459) Some output resolution timings are inexact.
(B14545) Not able to select “PC in” audio input for audio monitoring output.
(B14804) TSL service, Andromeda service and any Remote Control Commands cannot trigger tallies.
(B14805) Potential problem (crashes) when using Gateway alarms and texts with the same addresses
within a layout.
(14832) White dots in the Analog clock don’t display properly.
Version 3.10
New Features
Kaleido-Alto/Quad/Quad-Duals can now be configured to operate in cascade mode for up to 30 inputs on
one display.
(B12633) A Kaleido-Alto/Quad/Quad-Dual can now decode and display the VITC from video sources.
Fixes
(B12635) A line of noise appears at the bottom of the screen when setting the underscan mode
This problem has been fixed in version 3.10 via a firmware update.
Frequently Asked Questions (FAQ)
Q. Does the Kaleido-Alto/Quad/Quad-Dual come with a fixed IP address?
A. By default, the Kaleido-Alto/Quad/Quad-Dual is configured using DHCP. However, a fixed address can be
entered in the Network Configuration panel (see the User’s Manual for more information).
Q. Is it possible to upgrade the Kaleido-Alto-A, D and AD with version 2.1 or is new hardware needed?
A. Yes, an upgrade is possible. Visit http://www.miranda.com/portal/downloads.php to get the latest version
available. The upgrade package consists of firmware and software files that can be transferred from a client PC
via TCP/IP to a Kaleido-Alto, Layout and configuration files are not affected by the upgrade.