OTHERWISE, FOLLOW THE PROCEDURE
DESCRIBED IN SESSION 1.4.1 TO ENTER THE FACTORY MODE AGAIN
1.4.3 UNDER FACTORY MODE, PRESS “POWER” KEY. THE MONITOR WILL EXIT
FACTORY MODE AND ENTER NORMAL DISPLAY MODE.
1.5 METHOD TO ENTER/EXIT MANUAL COLOR ALIGNMENT MENU
UNDER FACTORY MODE, SELECT COLOR TEMP MANUAL. ITEM ON FACTORY OSD
MENU. IT WILL DISPLAY THE FOLLOWING COLOR TEMPERATURE ADJUST MENU.
USE “UP” AND “DOWN” TO MOVE CURSOR BETWEEN ITEMS “9300”, “6500”,”5400”
AND ”5000”. PRESS “2” TO SELECT WHICH COLOR TEMPERATURE TO BE ADJUSTED. IT
WILL SHOW FOLLOWING MENU.
USE “2” KEY TO SWITCH R, G, B, DRIVER. “UP” OR “DOWN” KEY TO ADJUST THE R. G.
B VALUE CORRESPONDING TO THE SELECTED ITEM.
!