Service manual

!
65!
5. Adjust Procedure
1. Preparation of manual alignment
1.1 The alignment procedure is performed after unit has been
completely assembled and before set inspection.
1.2 Before alignment, set should be burned-in for over 30MIN.
1.3 Measuring equipment used pre-programmed chroma 2226 or
equivalent products.
Color meter-- Minolta CA210 or equivalent products.
1.4 Methods to enter/exit factory mode
1.4.1 Press “2” and “down” key and power on to set the monitor to the burn-in
mode.
1.4.2 Press “vol-” and “1” key and power on to set the monitor to the factory
mode.
1.4.3 To ensure the monitor is under factory mode, check the status in the OSD
menu screen.
CA110
210 mm
ViewSonic Corporation
Confidential – Do Not Copy VX700-3