Service manual

5000°K ĺx = 0.346±0.030, y = 0.359±0.030 Y>= 190CD/M
2
.
2.4.3 Press “1” to exit 5000 color temperature adjustment and do another color
temperature adjustment. When exit factory mode OSD menu, the above
result R, G, B gains will automatically be saved.
3. Factory preset setting.
3.1 In factory mode OSD main menu, select factory default setting. Press “2” to
confirm the selection.
4. Download serial number procedure.
4.1 Plug adapter in ac source.
4.2 Press button 2 and down arrow key simultaneously, then press LCD power key.
4.3 In writeable system, key in twelve number or use bar code read in serial number.
4.4 Enter OUTPUT SN.
4.5 Pull out adapter.
ViewSonic Corporation
Confidential Do Not Copy
VG800b
54