Service manual
1. Preparation of manual alignment.
1.1 The alignment procedure is performed after unit has been completely assembled and before set
inspection.
1.2 Before set been aligned, set should be burned in for over 30min.
1.3 Measuring equipment used.
Pre-Programmed Chroma 2226 or equivalent products.
Color Meter-- Minolta CA110 or equivalent products.
1.4 Method to enter/exit factory mode.
1.4.1 Press “VOL+” and “1” and “DOWN” key simultaneously 3 times when set are power on
and display image.
1.4.2 To ensure the monitor is under factory mode, check following OSD image display on the
screen to ensure monitor is under factory mode.
Otherwise, follow the procedure described in session 1.4.1 to enter the factory mode
again.
1.4.3 Under factory mode, press “1” key. The monitor will exit factory mode and enter normal
operation.
1.5 Method to enter/exit manual color alignment menu.
Under factory mode, select color temp manual. Item on factory OSD menu. It will display the
following color temperature adjust menu.
CA110
210 mm
Firmware Version
Factory Mode
Factory Default
Color Temp. Manual
1 : Exit
2 : Select
ViewSonic Corporation
Confidential – Do Not Copy
VG800b