Service manual
37
ViewSonic Corporation Confidential - Do Not Copy PJ513D-1
i. Insert Lamp into HLD Lamp and push Lamp forward to touch DTM Lamp of HLD
Lamp (Fig. 1-11)
ii. To make sure that three datum contact with the lamp well(Fig. 1-12)
iii. After assemble Lamp to HLD Lamp, Hook “Clip down Lamp” first then Hook “Clip UP
Lamp” on the HLD Lamp to fix Lamp last. (Fig. 1-13、1-14)
iv. Check assembly again and make sure the three datum contact with the lamp.
v. Assemble Plate Lamp to the HLD Lamp and fasten the screw(Fig. 1-15)
Fig. 1-11 Fig. 1-12
Fig. 1-13 Fig. 1-14
DTM of Lamp