Service manual
33
ViewSonic Corporation Confidential - Do Not Copy PJ513D-1
5. YUV Alignment Procedure
Equipment:
- Pattern generator (VG-828)
OSD Default value:
Item Value
Cal R Offset 127
Cal G Offset 127
Cal B Offset 127
Cal R Gain 127
Cal G Gain 127
Cal B Gain 127
YPbPr R Offset 127
YPbPr B Offset 127
Procedure:
1. Connect power core, YPbPr cable into projector.
2. Change timing and pattern of pattern generator:
Timing: 480i
Pattern: As Figure2
3. Light on projector
4. Adjust user OSD values to default.
5. Enter factory mode.
6. Adjust Factory values to default.
7. Press “Calibration YPbPr” to calibrate the mid level offset.
Figure2