Service manual

4.4 Power On/Off Sequence
4.4.1 Hardware Power ON
When power cord is plugged into AC socket, SMPS starts work and provides U105 with VCC5V. When
VCC5V inputs, U105 resets circuit active, sets U105 all registers to preset modes, and then monitor goes into
stand-by mode. That means hardware power on has been completed.
4.4.2 Software Power ON/OFF
When press power key, U105 # 74 recieves low pulse,and then U105 will do the power on/off.
- If Power ON, U108 # 103(LED_Blue) will send out Low potential, and then LED Blue on.
- If Power OFF, U108 # 103(LED_ Blue) will send out High potential, and then LED Off.
The Panel_Vcc, Backlight_En, CLK/DATA output to panel will follow the following sequency.
T1 (ms) T2 (ms) T3 (ms) T4 (ms) T5 (ms) T6+T7 (ms)
0.5~10 0~50 500 90 0~50 500
4.4.3 AC Outlet Pin Assignment
Pin Symbol Description
1 L Live
2 N Neutral
3 E GND
P801
1 2
3
ViewSonic Corporation
VX2433wm-1
VX2433wm-CN
CONFIDENTIAL – DO NOT COP
Y
45