User guide
Other Information
35
Get-Mute 8 g g 67 000: Off
001: On (muted)
Get-Input select 8 g j 6A 000~ See Set-function table
Get-Power
status: ON/STBY
8 g l 6C 001: ON
000: STBY
Get-Remote
control
8 g n 6E 000: Disable
001: Enable
002: Pass through
Gets RCU mode status
Get-Power lock 8 g o 6F 000: Unlock
001: Lock
Get-Button lock 8 g p 70 000: Unlock
001: Lock
Get-Menu lock 8 g q 71 000: Unlock
001: Lock
Get-Setup
wizard
8 g s 73 000: Disable
001: Enable
Get-ACK 8 g z 7A 000 This command is used
to test the
communication link.
3.3 Remote Control Pass-through mode
When PC sets the LCD display to Remote Control Pass through mode, the LCD display shall send a 7 bytes
packet (followed by “CR”) in response to RCU button activation. Note, that in this mode the RCU shall
have no effect on the LCD display function. For example: “Volume+” will not change the volume in the
LCD but only sends “Volume+” code to PC over the RS232 port.
IR Pass Through-Function format
Reply: (Command Type= “p”)
Name
Length ID Command
Type
RCU Code1
(MSB)
RCU Code2
(LSB)
CR
Byte Count 1 Byte 2 Byte 1 Byte 1 Byte 1 Byte 1 Byte
Bytes order 1 2~3 4 5 6 7
Example1: Remote Control pass-through when “VOL+” key is pressed for TV-05
Reply (Hex Format)
Name
Length ID Command
Type
RCU Code1
(MSB)
RCU Code2
(LSB)
CR
Hex
0x36 0x30
0x35
0x70 0x31 0x30 0x0D
Key Code (HEX)
1 01
2 02
3 03
4 04
5 05
6 06