User guide
Other Information
30
3. Protocol
3.1 Set-Function Listing
The PC can control the LCD display for specic actions. The Set-Function command allows you to
control the LCD display behavior in a remote sit through the RS232 port. The Set-Function packet format
consists of 9 bytes.
Set-Function description:
Length:
Total Byte of Message excluding “CR”
ID:
Identication for each of LCD display
If we want to set all settings, ID can use “99” to achieve, and
it will not have Reply command on this function.
The ID can be set via the OSD menu for each set.
Command Type:
Identify command type,
“s” (0x73h) : Set Command
“+” (0x2Bh) : Valid command Reply
“-” (0x2Dh) : Invalid command Reply
Command:
Function command code: One byte ASCII code
Value[1~3]:
Three bytes ASCII that denes the value
CR:
0x0D
Set-Function format:
Send: (Command Type= “s”)
Name
Length ID Command
Type
Command Value1 Value2 Value3 CR
Byte Count 1 Byte 2 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte
Bytes order 1 2~3 4 5 6 7 8 9
Reply: (Command Type= “+” or “-”)
Name
Length ID Command Type CR
Byte Count 1 Byte 2 Byte 1 Byte 1 Byte
Bytes order 1 2~3 4 5
[NOTE] The reply for “Power on” command is the exception. It’s 0x322B0D ( 2+<CR>).
Example1: Set Brightness as 76 for TV-02 and this command is valid
Send (Hex Format)
Name
Length ID Command Type Command Value1 Value2 Value3 CR
Hex
0x38 0x30
0x32
0x73 0x24 0x30 0x37 0x36 0x0D
Reply (Hex Format)
Name
Length ID Command Type CR
Hex
0x34 0x30
0x32
0x2B 0x0D