Repair manual

R - Insert another 2-56 X ¼ in. Round head screw. Tighten this
screw with solid screwdriver.
S - Lubricate advance indicator threads with CD33. Install travel
indicator using special tool. Be sure that indicator is not
eccentric and paint is not chipped. This is done on cameras
above #9800 only. Install plastic window.
T - Replace top plate with three 0-90 screws. Check exposure
dial, with summer set at 10, average color and bright sun
lined up, setting should be F6.3 at 1/58±5%.
U - Check aperture dial and speed dial for free and even movement.
V - Check front view finder lens for chips.
22.000 FRONT
22.100 Remove Front
A - Remove bottom and back according to instructions. (Section
20.100)
B - Turn selector knob to “B” and wind. The first mounting screw
may be seen by looking between flash switch and front, and
between release button shaft and end of front casting, when
shutter blade spring is held out of the way. Remove this
screw. See photo for screw location.
C - Release shutter. The other mounting screw may be seen at the
other end of camera between the front and the frame. With
selector knob in “A” position, remove this screw.
D - Place camera face down on a bench and remove four 1-72 frame
mounting screw.
E - Unhook spring from release lever.
22.200 Replace Shutter
A - Remove bottom and back according to instructions. (Section
20.100)
B - Remove selector knob and crank assembly (118-524) by removing
screw on top of selector knob.
C - Remove shutter pad. Note how it is positioned in the front so
it can be replaced properly.
D - Remove lower selector blade retainer (Older models have a
screw holding lower retainer in place)
E - Remove selector plate.
F - Remove shutter blades by lifting front end and allowing the
shutter to go foreword.
G - Replace shutter blades with new ones if necessary. Be sure
shutter blades are free of oil and are clean. Rehook shutter
springs to front casting. If shutter bearing studs are worn
it may be necessary to burnish with a smooth edge of a piece
of sheet metal, or special file.
H - Replace selector plate with embossing toward front of casting
and the slot for selector wire assembly towards top of
casting.
I - Replace selector plate retainer and restake in position.
Retainers must be straight, not bent up or down. Selector
plate must slide freely and not interfere with shutter blades.
Shutter blades must of course, slide freely.