Installation Manual

8
5350 485 GB 08/2007
Technical Specification
General Specifications and Performance Data.
Vitodens 200-W WB2B
Appliance
System 19 kW System 26 kW System 30 kW System 35 kW
Mode Unit
Rated Central Heating Output
Tf/Tr 50/30 ºC (condensing) KW 4.8 to 19.0 6.5 to 26.0 8.8 to 30.0 8.8 to 35.0
Tf/Tr 80/60 ºC (non condensing) KW 4.3 to 17.5 5.9 to 24.1 7.9 to 27.8 7.9 to 32.2
Rated Central Heating Input (net) KW 4.5 to 17.9 6.2 to 24.7 8.3 to 28.5 8.3 to 33.0
Rated Central Heating Input (gross) kW 5.0 to 19.9 6.9 to 27.4 9.2 to 31.1 9.2 to 36.6
Maximum gas rate m3/h 1.89 2.61 3.01 3.49
Seasonal efficiency (SEDBUK) % 90.1 90.1 90.1 90.1
SEDBUK rating A
No
x
classification Class 5
Minimum CH system pressure - cold bar 1
Maximum CH system pressure - hot bar 2.5
CH flow temperature ºC 30 to 80
Integral expansion vessel capacity ltr 10
Integral expansion vessel pre-charge
pressure bar 0.75
Max CH system water content using
fitted expansion vessel @ 0.75 bar ltr 125
and 80ºC
Total water capacity ltr 7.2 7.8 8.2 8.2
Lift weight kg 43 45 47 47
Total weight (incl packaging) kg 48 50 52 52
Electricity supply 230v, 50Hz
Internal fuse A 6.3
Maximum power consumption W 85 95 115 115
Water protection rating IP x4D
Inner flue duct diameter mm 60
Outer flue duct diameter mm 100
Gas council number 41-819-14 41-819-15 41-819-16 41-819-17
Product ID CE-0085 BR 0432
Vitoden 200-W installation 4/9/07 7:27 pm Page 8