Installation Manual
60
5350 485 GB 08/2007
Setting the maximum CH output
1. Start the boiler
2. Press and simultaneously
until a value appears and flashes (e.g.
“85”) and appears. In the delivered
condition, this value represents 100% of
rated output. On weather compensated
control units, the display additionally
shows “Max Heating Output”.
3. With select the required
value in % of rated output as maximum
output.
4. Confirm the set value with
5. Record the settings for maximum output
on the additional type plate included
with the “technical documentation”. Affix
the type plate next to the original type
plate on top of the boiler.
Note
The output can also be limited for DHW
heating. For this, change coding address
“6F” in code 2.
Note
You can limit the maximum output for heating operation. The limit is set via the modulation
range. The max. adjustable heating output is limited by the boiler coding card.
/
+
_
OK