Installation Instructions
78
Rated voltage: 230 V~
Rated frequency: 50 Hz
Rated current: 2.0 A~
Safety category: I
IP rating: IP X4 to EN 60529
Permissible ambient temperature
■ during operation: 0 to +40 °C
■ during storage and
transport: -20 to +65 °C
Temperature limiter
setting: 100 °C (fixed)
Backup fuse (power
supply): 3 A
Gas boiler, category II
2H3P
Rated heating output
range in heating mode
T
V
/T
R
50/30 °C kW 6.5 – 19 6.5 – 26 8.8 – 30 8.8 – 35
T
V
/T
R
80/60 °C kW 5.9 –
17.3
5.9 –
23.7
8.0 –
27.3
8.0 – 31.9
Rated heating output
range
for DHW heating (gas con-
densing combi boiler)
kW —
5.9 –
26.0
8.0 –
30.0
8.0 – 35.0
Rated heat input range kW
6.1 –
17.8
6.1 –
24.3
8.2 –
28.0
8.2 – 32.7
Connection values
*1
relative to the max. load
with:
- Natural gas E
m
3
/h
1.9 2.6 3.0 3.5
- LPG P kg/h 1.4 1.9 2.2 2.6
Power consumption
(max.)
- Gas condensing boiler W 102 107 106 154
- Gas condensing combi
boiler
W — 119 132 158
Gas condensing combi
boiler (DHW heating)
Permiss. operating pres-
sure
bar — 10 10 10
*1
The connection values are only for documentation purposes (e.g. in the gas con-
tract application) or to estimate a supplementary volumetric settings check. Due to
the factory settings, the gas pressure must not be altered from these values. Ref-
erence: 15 °C, 1013 mbar.
Specification
Specification
5609 059 GB